Evidence map›Paper›PMID 35633946›Full record

ArticleIEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society2022

A Dexterous Robotic System for Autonomous Debridement of Osteolytic Bone Lesions in Confined Spaces: Human Cadaver Studies.

Shahriar Sefati, Rachel Hegeman, Iulian Iordachita, Russell H Taylor, Mehran Armand

Open access · hybridAbstract read
In one paragraph

Article in IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 43 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Platform for investigating continuum manipulator behavior in orthopedics.International journal of computer assisted radiology and surgery · 2023
    Article
  5. Article
  6. Data-driven Shape Sensing of Continuum Dexterous Manipulators Using Embedded Capacitive Sensor.Proceedings of IEEE Sensors. IEEE International Conference on Sensors · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Shahriar SefatiLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218 USA.ORCID 0000-0003-1989-3796
Rachel HegemanLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218 USA.ORCID 0000-0003-2869-8773
Iulian IordachitaLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218 USA.ORCID 0000-0002-2510-9008
Russell H TaylorLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218 USA.ORCID 0000-0001-6272-1100
Mehran ArmandDepartment of Orthopedic Surgery, The Johns Hopkins Medical School, Baltimore, MD 21205 USA.ORCID 0000-0003-1028-8303
Johns Hopkins University · US

Funding

Image-Guided Workstation and Tools for the Treatment of Bone DefectsR01EB016703 · NIBIB · UNIVERSITY OF ARKANSAS AT FAYETTEVILLE · PI ARMAND, MEHRAN · 2013 to 2022
$3.4M
NIBIB NIH HHS R01 EB016703
6 · The paper itself

Abstract

This article presents a dexterous robotic system for autonomous debridement of osteolytic bone lesions in confined spaces. The proposed system is distinguished from the state-of-the-art orthopedics systems because it combines a rigid-link robot with a continuum manipulator (CM) that enhances reach in difficult-to-access spaces often encountered in surgery. The CM is equipped with flexible debriding instruments and fiber Bragg grating sensors. The surgeon plans on the patient's preoperative computed tomography and the robotic system performs the task autonomously under the surgeon's supervision. An optimization-based controller generates control commands on the fly to execute the task while satisfying physical and safety constraints. The system design and controller are discussed and extensive simulation, phantom and human cadaver experiments are carried out to evaluate the performance, workspace, and dexterity in confined spaces. Mean and standard deviation of target placement are 0.5 and 0.18 mm, and the robotic system covers 91% of the workspace behind an acetabular implant in treatment of hip osteolysis, compared to the 54% that is achieved by conventional rigid tools.

Indexed as

Autonomy in medical roboticsdexterous continuum manipulator (CM)minimally invasive surgeryorthopedic surgery

Identifiers

PMID35633946
PMCPMC9138669
OpenAlexW3200209451

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked