ArticleNanomaterials (Basel, Switzerland)2022

Bimodal Interventional Instrument Markers for Magnetic Particle Imaging and Magnetic Resonance Imaging-A Proof-of-Concept Study.

Franz Wegner, Kerstin Lüdtke-Buzug, Sjef Cremers, Thomas Friedrich, Malte M Sieren, Julian Haegele, Martin A Koch, Emine U Saritas, Paul Borm, Thorsten M Buzug and 2 more

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Bare-Metal Stent Tracking with Magnetic Particle Imaging.International journal of nanomedicine · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Franz WegnerDepartment of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, 23562 Luebeck, Germany.ORCID 0000-0001-5969-3428
Kerstin Lüdtke-BuzugInstitute of Medical Engineering, University of Luebeck, 23538 Luebeck, Germany.
Sjef CremersNano4Imaging, 40225 Duesseldorf, Germany.
Thomas FriedrichInstitute of Medical Engineering, University of Luebeck, 23538 Luebeck, Germany.
Malte M SierenDepartment of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, 23562 Luebeck, Germany.
Julian HaegeleZentrum für Radiologie und Nuklearmedizin, 04103 Dormagen, Germany.
Martin A KochInstitute of Medical Engineering, University of Luebeck, 23538 Luebeck, Germany.
Emine U SaritasDepartment of Electrical and Electronics Engineering, Bilkent University, 06800 Ankara, Turkey.ORCID 0000-0001-8551-1077
Paul BormNano4Imaging, 40225 Duesseldorf, Germany.
Thorsten M BuzugInstitute of Medical Engineering, University of Luebeck, 23538 Luebeck, Germany.
Joerg BarkhausenDepartment of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, 23562 Luebeck, Germany.ORCID 0000-0001-8937-1198
Mandy AhlborgInstitute of Medical Engineering, University of Luebeck, 23538 Luebeck, Germany.

Funding

Federal Ministry of Education and Research 01DL17010A, 01DL17010BScientific and Technological Research Institution of Turkey TUBITAK 115E677
6 · The paper itself

Abstract

The purpose of this work was to develop instrument markers that are visible in both magnetic particle imaging (MPI) and magnetic resonance imaging (MRI). The instrument markers were based on two different magnetic nanoparticle types (synthesized in-house KLB and commercial Bayoxide E8706). Coatings containing one of both particle types were fabricated and measured with a magnetic particle spectrometer (MPS) to estimate their MPI performance. Coatings based on both particle types were then applied on a segment of a nonmetallic guidewire. Imaging experiments were conducted using a commercial, preclinical MPI scanner and a preclinical 1 tesla MRI system. MPI image reconstruction was performed based on system matrices measured with dried KLB and Bayoxide E8706 coatings. The bimodal markers were clearly visible in both methods. They caused circular signal voids in MRI and areas of high signal intensity in MPI. Both the signal voids as well as the areas of high signal intensity were larger than the real marker size. Images that were reconstructed with a Bayoxide E8706 system matrix did not show sufficient MPI signal. Instrument markers with bimodal visibility are essential for the perspective of monitoring cardiovascular interventions with MPI/MRI hybrid systems.

Indexed as

endovascular interventionshybrid imaginginterventional devicesmagnetic particle imagingmagnetic resonance imagingnanoparticles

Identifiers

PMID35630979
PMCPMC9148153

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.