Evidence map›Paper›PMID 35630833›Full record

ArticleMolecules (Basel, Switzerland)2022

Determination of Glycerophospholipids in Biological Material Using High-Performance Liquid Chromatography with Charged Aerosol Detector HPLC-CAD-A New Approach for Isolation and Quantification.

Magdalena Rosłon, Małgorzata Jaworska, Elżbieta L Anuszewska

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Review
  3. Simultaneous Extraction and Determination of Lignans fromMolecules (Basel, Switzerland) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Magdalena RosłonDepartment of Biochemistry and Biopharmaceuticals, National Medicines Institute, Chełmska 30/34, 00-725 Warsaw, Poland.
Małgorzata JaworskaDepartment of Biochemistry and Biopharmaceuticals, National Medicines Institute, Chełmska 30/34, 00-725 Warsaw, Poland.ORCID 0000-0001-8339-5690
Elżbieta L AnuszewskaDepartment of Biochemistry and Biopharmaceuticals, National Medicines Institute, Chełmska 30/34, 00-725 Warsaw, Poland.
Narodowy Instytut Leków · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The method of using high-performance liquid chromatography with a charged aerosol detector method (HPLC-CAD) was developed for the separation and determination of phospholipids isolated from cell membranes. The established cell lines-normal and neoplastic prostate cells and normal skin fibroblasts and melanoma cells-were selected for the study. Chromatographic separation was performed in the diol stationary phase using a gradient elution based on a mixture of n-hexane, isopropanol and water with the addition of triethylamine and acetic acid as buffer additives. Taking the elements of the Folch and Bligh-Dyer methods, an improved procedure for lipid isolation from biological material was devised. Ultrasound-assisted extraction included three extraction steps and changed the composition of the extraction solvent, which led to higher recovery of the tested phospholipids. This method was validated by assessing the analytical range, precision, intermediate precision and accuracy. The analytical range was adjusted to the expected concentrations in cell extracts of various origins (from 40 µg/mL for PS up to 10 mg/mL for PC). Both precision and intermediate precision were at a similar level and ranged from 3.5% to 9.0%. The recovery for all determined phospholipids was found to be between 95% and 110%. The robustness of the method in terms of the use of equivalent columns was also confirmed. Due to the curvilinear response of CAD, the quantification was based on an internal standard method combined with a power function transformation of the normalized peak areas, allowing the linearization of the signal with an

Indexed as

GlycerophospholipidsPhospholipidsAerosolsChromatography, High Pressure LiquidSolventsAerosolsGlycerophospholipidsPhospholipidsSolventscell membranesglycerophospholipidsHPLC-CAD

Identifiers

PMID35630833
PMCPMC9146369
OpenAlexW4281477941

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.