ArticleMicromachines2022
Frequency Characteristics of Pulse Wave Sensor Using MEMS Piezoresistive Cantilever Element.
Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Wearable, broadband auscultation patch with cantilever pressure transducer for remote healthcare monitoring.Nature communications · 2026Article
- A conformable shape-stable self-healing polymer platform for continuous wireless arterial pulse monitoring.Nature communications · 2026Article
- Assessment of a Calibration-Free Method of Cuffless Blood Pressure Measurement: A Pilot Study.IEEE journal of translational engineering in health and medicine · 2023Article
- An Arterial Compliance Sensor for Cuffless Blood Pressure Estimation Based on Piezoelectric and Optical Signals.Micromachines · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Wearable sensor devices with minimal discomfort to the wearer have been widely developed to realize continuous measurements of vital signs (body temperature, blood pressure, respiration rate, and pulse wave) in many applications across various fields, such as healthcare and sports. Among them, microelectromechanical systems (MEMS)-based differential pressure sensors have garnered attention as a tool for measuring pulse waves with weak skin tightening. Using a MEMS-based piezoresistive cantilever with an air chamber as the pressure change sensor enables highly sensitive pulse-wave measurements to be achieved. Furthermore, the initial static pressure when attaching the sensor to the skin is physically excluded because of air leakage around the cantilever, which serves as a high-pass filter. However, if the frequency characteristics of this mechanical high-pass filter are not appropriately designed, then the essential information of the pulse-wave measurement may not be reflected. In this study, the frequency characteristics of a sensor structure is derived theoretically based on the air leakage rate and chamber size. Subsequently, a pulse wave sensor with a MEMS piezoresistive cantilever element, two air chambers, and a skin-contacted membrane is designed and fabricated. The developed sensor is 30 mm in diameter and 8 mm in thickness and realizes high-pass filter characteristics of 0.7 Hz. Finally, pulse wave measurement at the neck of a participant is demonstrated using the developed sensor. It is confirmed that the measured pulse wave contains signals in the designed frequency band.