Evidence map›Paper›PMID 35630112›Full record

ArticleMicromachines2022

Frequency Characteristics of Pulse Wave Sensor Using MEMS Piezoresistive Cantilever Element.

Taiga Nabeshima, Thanh-Vinh Nguyen, Hidetoshi Takahashi

Abstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Assessment of a Calibration-Free Method of Cuffless Blood Pressure Measurement: A Pilot Study.IEEE journal of translational engineering in health and medicine · 2023
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Taiga NabeshimaDepartment of Mechanical Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kouhoku-ku, Yokohama 223-8522, Kanagawa, Japan.
Thanh-Vinh NguyenSensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba 305-8564, Ibaraki, Japan.
Hidetoshi TakahashiDepartment of Mechanical Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kouhoku-ku, Yokohama 223-8522, Kanagawa, Japan.ORCID 0000-0002-0754-3281

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable sensor devices with minimal discomfort to the wearer have been widely developed to realize continuous measurements of vital signs (body temperature, blood pressure, respiration rate, and pulse wave) in many applications across various fields, such as healthcare and sports. Among them, microelectromechanical systems (MEMS)-based differential pressure sensors have garnered attention as a tool for measuring pulse waves with weak skin tightening. Using a MEMS-based piezoresistive cantilever with an air chamber as the pressure change sensor enables highly sensitive pulse-wave measurements to be achieved. Furthermore, the initial static pressure when attaching the sensor to the skin is physically excluded because of air leakage around the cantilever, which serves as a high-pass filter. However, if the frequency characteristics of this mechanical high-pass filter are not appropriately designed, then the essential information of the pulse-wave measurement may not be reflected. In this study, the frequency characteristics of a sensor structure is derived theoretically based on the air leakage rate and chamber size. Subsequently, a pulse wave sensor with a MEMS piezoresistive cantilever element, two air chambers, and a skin-contacted membrane is designed and fabricated. The developed sensor is 30 mm in diameter and 8 mm in thickness and realizes high-pass filter characteristics of 0.7 Hz. Finally, pulse wave measurement at the neck of a participant is demonstrated using the developed sensor. It is confirmed that the measured pulse wave contains signals in the designed frequency band.

Indexed as

frequency characteristicspiezoresistive cantileverpulse wave sensor

Identifiers

PMID35630112
PMCPMC9144857

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.