In Vivo Accuracy of a New Digital Planning System in Terms of Jaw Relation, Extent of Surgical Movements and the Hierarchy of Stability in Orthognathic Surgery.

Thomas Stamm, Eugenia Andriyuk, Johannes Kleinheinz, Susanne Jung, Dieter Dirksen, Claudius Middelberg

Abstract read
In one paragraph

Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Treatment of skeletal class III malocclusion using a combined clear aligner and surgery-early approach : Assessment based on the American Board of Orthodontics Objective Grading System.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2024
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Thomas StammDepartment of Orthodontics, University of Münster, Albert-Schweitzer-Campus 1, 48149 Münster, Germany.ORCID 0000-0003-1260-2650
Eugenia AndriyukDepartment of Orthodontics, University of Münster, Albert-Schweitzer-Campus 1, 48149 Münster, Germany.
Johannes KleinheinzDepartment of Cranio-Maxillofacial Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149 Münster, Germany.
Susanne JungDepartment of Cranio-Maxillofacial Surgery, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149 Münster, Germany.
Dieter DirksenDepartment of Prosthetic Dentistry and Biomaterials, University Hospital Münster, Albert-Schweitzer-Campus 1, 48149 Münster, Germany.
Claudius MiddelbergDepartment of Orthodontics, University of Münster, Albert-Schweitzer-Campus 1, 48149 Münster, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This retrospective cohort study compares the virtual planned and postoperative jaw positions in patients undergoing orthognathic surgery. Surgery was virtually planned with the Digital Münster Model Surgery system (DMMS). Primary outcome: Spatial difference in the maxillo-mandibulo relation between virtual planning and postoperative result. Secondary outcome: Possible relationship between the measured differences and surgical movements as well as the postoperative stability according to Proffit. Ninety female and sixty-one male patients were included in the study. The average translation errors were 0.54 ± 0.50 mm (anteroposterior), 0.37 ± 0.33 mm (mediolateral), and 0.33 ± 0.28 mm (superoinferior). Orientation errors were 0.86 ± 0.79 degrees (yaw), 0.54 ± 0.48 degrees (roll), and 0.90 ± 0.72 degrees (pitch). The surgical procedures do not differ with respect to their error sizes. Maxilla forward and class II maxilla up with mandible forward are the most precise procedures. Most significant differences were found in the anteroposterior direction, whereby the extent of the surgical movement has no effect on the magnitude of the error. The process of planning with the DMMS followed by surgery is highly accurate and shows error values well below the clinically accepted limit of two millimeters in translation and four degrees in rotation.