Evidence map›Paper›PMID 35627340›Full record

ArticleInternational journal of environmental research and public health2022

Safety and Effectiveness of Transvenous Lead Extraction in Patients with Infected Cardiac Resynchronization Therapy Devices; Is It More Risky than Extraction of Other Systems?

Paweł Stefańczyk, Dorota Nowosielecka, Anna Polewczyk, Łukasz Tułecki, Konrad Tomków, Wojciech Jacheć, Ewa Lewicka, Andrzej Tomaszewski, Andrzej Kutarski

Open access · goldAbstract read
In one paragraph

Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 1 country.

Paweł StefańczykDepartment of Cardiology, The Pope John Paul II Province Hospital of Zamość Poland, 22-400 Zamość, Poland.ORCID 0000-0002-4106-3804
Dorota NowosieleckaDepartment of Cardiology, The Pope John Paul II Province Hospital of Zamość Poland, 22-400 Zamość, Poland.ORCID 0000-0002-2441-3876
Anna PolewczykDepartment of Physiology, Patophysiology and Clinical Immunology, Collegium Medicum of Jan Kochanowski University, 25-369 Kielce, Poland.ORCID 0000-0002-6632-6551
Łukasz TułeckiDepartment of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość Poland, 22-400 Zamość, Poland.
Konrad TomkówDepartment of Cardiac Surgery, The Pope John Paul II Province Hospital of Zamość Poland, 22-400 Zamość, Poland.
Wojciech JachećDepartment of Cardiology, Faculty of Medical Science in Zabrze, Medical University of Silesia, 40-752 Katowice, Poland.ORCID 0000-0002-1091-9788
Ewa LewickaDepartment of Cardiology and Electrocardiotherapy, Medical University of Gdańsk, 80-416 Gdańsk, Poland.
Andrzej TomaszewskiDepartment of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland.
Andrzej KutarskiDepartment of Cardiology, Medical University of Lublin, 20-059 Lublin, Poland.
John Paul II Hospital · PLMedical University of Lublin · PLGdańsk Medical University · PLJan Kochanowski University · PLMedical University of Silesia · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transvenous lead extraction (TLE) in patients with implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as more risky. The aim of this study was to assess the safety and effectiveness of TLE in patients with infected CRT systems. Methods: Data of 3468 patients undergoing TLE in a single high-volume center in years 2006−2021 were analyzed. The clinical and procedural parameters as well as the efficacy and safety of TLE were compared between patients with infected CRT and pacemakers (PM) and ICD systems. Results: Infectious indications for TLE occurred in 1138 patients, including 150 infected CRT (112 CRT-D and 38 CRT-P). The general health condition of CRT patients was worse with higher Charlson’s comorbidity index. The number of extracted leads was higher in the CRT group, but implant duration was significantly longer in the PM than in the ICD and CRT groups (98.93 vs. 55.26 vs. 55.43 months p < 0.01). The procedure was longer in duration, more difficult, and more complex in patients with pacemakers than in those in the CRT group. The occurrence of major complications and clinical and procedural success as well as procedure-related death did not show any relationship to the type of CIED device. Mortality at more than one-year follow-up after TLE was significantly higher among patients with CRT devices (22.7% vs. 8.7%) than among those in the PM group. Conclusion: Despite the greater burden of lead and comorbidities, the complexity and efficiency of removing infected CRT systems is no more dangerous than removing other infected systems. The duration of the implant seems to play a dominant role.

Indexed as

Cardiac Resynchronization Therapy DevicesDefibrillators, ImplantableComorbidityDevice RemovalHumansLeadLeadcardiac resynchronization therapyinfectious indicationssafety and effectivenesstransvenous lead extraction

Identifiers

PMID35627340
PMCPMC9141355
OpenAlexW4229453391

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.