Evidence map›Paper›PMID 35626318›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Rapid Quantum Magnetic IL-6 Point-of-Care Assay in Patients Hospitalized with COVID-19.

Johnny Atallah, Dakota Archambault, Jeffrey D Randall, Adam Shepro, Lauren E Styskal, David R Glenn, Colin B Connolly, Katelin Katsis, Kathleen Gallagher, Musie Ghebremichael and 1 more

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Quantum sensors for biomedical applications.Nature reviews. Physics · 2023
    Review
  4. COVID Diagnostics: From Molecules to Omics.Advances in experimental medicine and biology · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 1 country.

Johnny AtallahDivision of Infectious Diseases, Massachusetts General Hospital, Boston, MA 02114, USA.ORCID 0000-0003-0681-9087
Dakota ArchambaultDivision of Infectious Diseases, Massachusetts General Hospital, Boston, MA 02114, USA.
Jeffrey D RandallQuantum Diamond Technologies Inc., Somerville, MA 02143, USA.
Adam SheproQuantum Diamond Technologies Inc., Somerville, MA 02143, USA.
Lauren E StyskalQuantum Diamond Technologies Inc., Somerville, MA 02143, USA.
David R GlennQuantum Diamond Technologies Inc., Somerville, MA 02143, USA.
Colin B ConnollyQuantum Diamond Technologies Inc., Somerville, MA 02143, USA.
Katelin KatsisDepartment of Medicine, Harvard Medical School, Boston, MA 02115, USA.
Kathleen GallagherDepartment of Medicine, Harvard Medical School, Boston, MA 02115, USA.
Musie GhebremichaelDepartment of Medicine, Harvard Medical School, Boston, MA 02115, USA.
Michael K MansourDivision of Infectious Diseases, Massachusetts General Hospital, Boston, MA 02114, USA.
Harvard University · USQuantum Diamond Technologies (United States) · US

Funding

The role of spleen tyrosine kinase (syk) in neutrophil responses to pathogenic fungi.R01AI132638 · NIAID · MASSACHUSETTS GENERAL HOSPITAL · PI MANSOUR, MICHAEL K · 2018 to 2021
$1.6M
NIAID NIH HHS R01 AI132638NIH HHS AI132638
6 · The paper itself

Abstract

Interleukin-6 (IL-6) has been linked to several life-threatening disease processes. Developing a point-of-care testing platform for the immediate and accurate detection of IL-6 concentrations could present a valuable tool for improving clinical management in patients with IL-6-mediated diseases. Drawing on an available biobank of samples from 35 patients hospitalized with COVID-19, a novel quantum-magnetic sensing platform is used to determine plasma IL-6 concentrations. A strong correlation was observed between IL-6 levels measured by QDTI10x and the Luminex assay (r = 0.70, p-value < 0.001) and between QDTI80x and Luminex (r = 0.82, p-value < 0.001). To validate the non-inferiority of QDTI to Luminex in terms of the accuracy of IL-6 measurement, two clinical parameters—the need for intensive care unit admission and the need for mechanical intubation—were chosen. IL-6 concentrations measured by the two assays were compared with respect to these clinical outcomes. Results demonstrated a comparative predictive performance between the two assays with a significant correlation coefficient. Conclusion: In short, the QDTI assay holds promise for implementation as a potential tool for rapid clinical decision in patients with IL-6-mediated diseases. It could also reduce healthcare costs and enable the development of future various biomolecule point-of-care tests for different clinical scenarios.

Indexed as

COVID-19diagnosticsICUIL-6Luminexmechanical ventilationQDTI

Identifiers

PMID35626318
PMCPMC9139897
OpenAlexW4229332175

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.