Evidence map›Paper›PMID 35626217›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Lower Macromolecular Content in Tendons of Female Patients with Osteoporosis versus Patients with Osteopenia Detected by Ultrashort Echo Time (UTE) MRI.

Saeed Jerban, Yajun Ma, Amir Masoud Afsahi, Alecio Lombardi, Zhao Wei, Meghan Shen, Mei Wu, Nicole Le, Douglas G Chang, Christine B Chung and 2 more

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.8field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Ultrashort echo time MRI detects significantly lower collagen but higher pore water in the tibial cortex of female patients with osteopenia and osteoporosis.Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 1 institution in 1 country.

Saeed JerbanDepartment of Radiology, University of California, San Diego, CA 92093, USA.
Yajun MaDepartment of Radiology, University of California, San Diego, CA 92093, USA.
Amir Masoud AfsahiDepartment of Radiology, University of California, San Diego, CA 92093, USA.
Alecio LombardiDepartment of Radiology, University of California, San Diego, CA 92093, USA.
Zhao WeiDepartment of Radiology, University of California, San Diego, CA 92093, USA.
Meghan ShenDepartment of Radiology, University of California, San Diego, CA 92093, USA.ORCID 0000-0002-0447-0160
Mei WuDepartment of Radiology, University of California, San Diego, CA 92093, USA.
Nicole LeDepartment of Radiology, University of California, San Diego, CA 92093, USA.
Douglas G ChangDepartment of Orthopaedic Surgery, University of California, San Diego, CA 92093, USA.
Christine B ChungDepartment of Radiology, University of California, San Diego, CA 92093, USA.
Jiang DuDepartment of Radiology, University of California, San Diego, CA 92093, USA.
Eric Y ChangDepartment of Radiology, University of California, San Diego, CA 92093, USA.ORCID 0000-0003-3633-5630
University of California San Diego · US

Funding

Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of BoneR01AR068987 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DU, JIANG · 2015 to 2024
$4.9M
Quantitative UTE MR Imaging: Sensitive Biomarkers for OsteoarthritisR01AR062581 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DU, JIANG · 2013 to 2022
$4.1M
Ultrashort Echo Time Magnetic Resonance Imaging of the Lumbar Intervertebral Disc.R01AR079484 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI Yajun Ma · 2022 to 2026
$2.7M
Three-dimensional Ultrashort Echo Time Magnetic Resonance Imaging of EnthesesR01AR075825 · NIAMS · VETERANS MEDICAL RESEARCH FDN/SAN DIEGO · PI CHANG, ERIC Y · 2019 to 2023
$1.8M
Knee evaluation under mechanical loading by cones ultrashort echo time MR imagingK01AR080257 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI saeed jerban · 2022 to 2026
$602k
Quantitative Measurement of Joint pH with Magnetic Resonance ImagingI01RX002604 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2018 to 2022
–
Quantitative Magnetic Resonance Imaging of Human Rotator Cuff TendonI01CX001388 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2016 to 2024
–
Ultrashort TE MR Imaging of Femorotibial CartilageI01CX000625 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHRISTINE B CHUNG · 2012 to 2026
–
CSRD VA I01 CX000625CSRD VA I01 CX001388National Institute of Health R01AR068987, R01AR062581, R01AR075825, and K01AR080257NIAMS NIH HHS K01 AR080257NIAMS NIH HHS R01 AR062581NIAMS NIH HHS R01 AR068987NIAMS NIH HHS R01 AR075825NIAMS NIH HHS R01 AR079484RRD VA I01 RX002604VA San Diego Healthcare System I01CX001388 and I01RX002604
6 · The paper itself

Abstract

Tendons and bones comprise a special interacting unit where mechanical, biochemical, and metabolic interplays are continuously in effect. Bone loss in osteoporosis (OPo) and its earlier stage disease, osteopenia (OPe), may be coupled with a reduction in tendon quality. Noninvasive means for quantitatively evaluating tendon quality during disease progression may be critically important for the improvement of characterization and treatment optimization in patients with bone mineral density disorders. Though clinical magnetic resonance imaging (MRI) sequences are not typically capable of directly visualizing tendons, ultrashort echo time MRI (UTE-MRI) is able to acquire a high signal from tendons. Magnetization transfer (MT) modeling combined with UTE-MRI (i.e., UTE-MT-modeling) can indirectly assess macromolecular proton content in tendons. This study aimed to determine whether UTE-MT-modeling could detect differences in tendon quality across a spectrum of bone health. The lower legs of 14 OPe (72 ± 6 years) and 31 OPo (73 ± 6 years) female patients, as well as 30 female participants with normal bone (Normal-Bone, 36 ± 19 years), are imaged using UTE sequences on a 3T MRI scanner. Institutional review board approval is obtained for the study, and all recruited subjects provided written informed consent. A T1 measurement and UTE-MT-modeling are performed on the anterior tibialis tendon (ATT), posterior tibialis tendon (PTT), and the proximal Achilles tendon (PAT) of all subjects. The macromolecular fraction (MMF) is estimated as the main measure from UTE-MT-modeling. The mean MMF in all the investigated tendons was significantly lower in OPo patients compared with the Normal-Bone cohort (mean difference of 24.2%, p < 0.01), with the largest Normal-Bone vs. OPo difference observed in the ATT (mean difference of 32.1%, p < 0.01). Average MMF values of all the studied tendons are significantly lower in the OPo cohort compared with the OPe cohort (mean difference 16.8%, p = 0.02). Only the PPT shows significantly higher T1 values in OPo patients compared with the Normal-Bone cohort (mean difference 17.6%, p < 0.01). Considering the differences between OPo and OPe groups with similar age ranges, tendon deterioration associated with declining bone health was found to be larger than a priori detected differences caused purely by aging, highlighting UTE-MT MRI techniques as useful methods in assessing tendon quality over the course of progressive bone weakening.

Indexed as

agingmacromolecular protonmagnetization transferMRItendonultrashort TE

Identifiers

PMID35626217
PMCPMC9140093
OpenAlexW4224322583

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked