Evidence map›Paper›PMID 35626015›Full record

ReviewCancers2022

The Role of Indocyanine Green Fluorescence in Rectal Cancer Robotic Surgery: A Narrative Review.

Elena Belloni, Edoardo Maria Muttillo, Salomone Di Saverio, Marcello Gasparrini, Antonio Brescia, Giuseppe Nigri

Open access · goldAbstract readReview
In one paragraph

Review in Cancers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Elena BelloniOncologic Colorectal Surgical Unit and Robotic Surgery Unit, Department of Medical and Surgical Sciences and Translational Medicine, Sapienza University of Rome, 00189 Rome, Italy.
Edoardo Maria MuttilloOncologic Colorectal Surgical Unit and Robotic Surgery Unit, Department of Medical and Surgical Sciences and Translational Medicine, Sapienza University of Rome, 00189 Rome, Italy.ORCID 0000-0003-3562-0392
Salomone Di SaverioDepartment of General Surgery, ASUR Marche, AV5, Hospital of San Benedetto del Tronto, 63074 San Benedetto del Tronto, Italy.
Marcello GasparriniOncologic Colorectal Surgical Unit and Robotic Surgery Unit, Department of Medical and Surgical Sciences and Translational Medicine, Sapienza University of Rome, 00189 Rome, Italy.
Antonio BresciaOncologic Colorectal Surgical Unit and Robotic Surgery Unit, Department of Medical and Surgical Sciences and Translational Medicine, Sapienza University of Rome, 00189 Rome, Italy.
Giuseppe NigriOncologic Colorectal Surgical Unit and Robotic Surgery Unit, Department of Medical and Surgical Sciences and Translational Medicine, Sapienza University of Rome, 00189 Rome, Italy.ORCID 0000-0002-7656-7789
Sapienza University of Rome · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn rectal cancer surgery, anastomotic leakage (AL) remains the most feared complication, with a frequency of up to 30% in non-high-volume centers. The preservation of proper vascularization is a key factor for successful anastomosis. The use of fluorescence with indocyanine green (ICG) as an intraoperative method to verify optimal perfusion is becoming an interesting tool in rectal surgery. Today, robotic surgery, together with the use of the intraoperative evaluation of the perfusion with ICG, could be a real strategy to deal with AL, allowing for a more delicate and less traumatic surgical technique. This strategy may allow for an extremely accurate surgery, and for optimal control of the proper vascularization of the rectum.

methodsThe purpose of this descriptive review is to analyze the impact of fluorescence and robotic surgery on short-term surgical outcomes for rectal cancer.

resultsWe performed a systematic literature search using the PubMed, Embase and Cochrane library databases. The primary endpoints were to evaluate the application of ICG fluorescence in robotic rectal surgery and the rate of anastomotic leakage when using these technological implementations. The secondary endpoints were to evaluate the dosage of ICG and the timing of application by different surgeons.

conclusionsICG fluorescence is an inexpensive and quick method to assess bowel perfusion, providing immediate feedback to the surgeon, even if its role has not been proven. A quantitative system must be systematically introduced to minimize the subjectiveness of the visualized image.

Indexed as

anastomotic leakagefluorescence surgeryrectal cancerrobotic rectal cancerrobotic surgery

Identifiers

PMID35626015
PMCPMC9139806
OpenAlexW4280528419

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.