Evidence map›Paper›PMID 35625700›Full record

ArticleBiomedicines2022

Novel Tissue-Engineered Multimodular Hyaluronic Acid-Polylactic Acid Conduits for the Regeneration of Sciatic Nerve Defect.

Fernando Gisbert Roca, Luis Gil Santos, Manuel Mata Roig, Lara Milian Medina, Cristina Martínez-Ramos, Manuel Monleón Pradas

Open access · goldAbstract read
In one paragraph

Article in Biomedicines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.8field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Review
  8. Review
  9. Article
  10. Review
  11. Review
  12. Article
  13. Review
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Fernando Gisbert RocaCenter for Biomaterials and Tissue Engineering, Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0003-3937-5822
Luis Gil SantosCenter for Biomaterials and Tissue Engineering, Universitat Politècnica de València, 46022 Valencia, Spain.
Manuel Mata RoigDepartment of Pathology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain.
Lara Milian MedinaDepartment of Pathology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain.
Cristina Martínez-RamosCenter for Biomaterials and Tissue Engineering, Universitat Politècnica de València, 46022 Valencia, Spain.
Manuel Monleón PradasCenter for Biomaterials and Tissue Engineering, Universitat Politècnica de València, 46022 Valencia, Spain.
Universitat de València · ESUniversitat Politècnica de València · ESBiomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine · ESUniversitat Jaume I · ES

Funding

Spanish Government's State Research Agency DPI2015-72863-EXPSpanish Government's State Research Agency RTI2018-095872-B-C22/ERDF
6 · The paper itself

Abstract

The gold standard for the treatment of peripheral nerve injuries, the autograft, presents several drawbacks, and engineered constructs are currently suitable only for short gaps or small diameter nerves. Here, we study a novel tissue-engineered multimodular nerve guidance conduit for the treatment of large nerve damages based in a polylactic acid (PLA) microfibrillar structure inserted inside several co-linear hyaluronic acid (HA) conduits. The highly aligned PLA microfibers provide a topographical cue that guides axonal growth, and the HA conduits play the role of an epineurium and retain the pre-seeded auxiliary cells. The multimodular design increases the flexibility of the device. Its performance for the regeneration of a critical-size (15 mm) rabbit sciatic nerve defect was studied and, after six months, very good nerve regeneration was observed. The multimodular approach contributed to a better vascularization through the micrometrical gaps between HA conduits, and the pre-seeded Schwann cells increased axonal growth. Six months after surgery, a cross-sectional available area occupied by myelinated nerve fibers above 65% at the central and distal portions was obtained when the multimodular device with pre-seeded Schwann cells was employed. The results validate the multi-module approach for the regeneration of large nerve defects and open new possibilities for surgical solutions in this field.

Indexed as

aligned substrateshyaluronic acidnerve guidance conduitnerve regenerationpolylactic acidSchwann cells

Identifiers

PMID35625700
PMCPMC9138968
OpenAlexW4224276779

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.