Evidence map›Paper›PMID 35624641›Full record

ArticleBiosensors2022

Bead Number Effect in a Magnetic-Beads-Based Digital Microfluidic Immunoassay.

Wensyang Hsu, Yu-Teng Shih, Meng-Shiue Lee, Hong-Yuan Huang, Wan-Ning Wu

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Aptamer-functionalized polydiacetylene biosensor for the detection of three foodborne pathogens.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2024
    Article
  5. Magnetic Bead Manipulation in Microfluidic Chips for Biological Application.Cyborg and bionic systems (Washington, D.C.) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Wensyang HsuDepartment of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan.
Yu-Teng ShihDepartment of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan.
Meng-Shiue LeeDepartment of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan.
Hong-Yuan HuangDepartment of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan.
Wan-Ning WuDepartment of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Taoyuan 33305, Taiwan.
National Yang Ming Chiao Tung University · TWChang Gung Memorial Hospital · TWChang Gung University · TW

Funding

Chang Gung Memorial Hospital Taiwan CMRPG3L0761Ministry of Science and Technology Taiwan MOST 109-2221-E-009-012-MY2
6 · The paper itself

Abstract

In a biomedical diagnosis with a limited sample volume and low concentration, droplet-based microfluidics, also called digital microfluidics, becomes a very attractive approach. Previously, our group developed a magnetic-beads-based digital microfluidic immunoassay with a bead number of around 100, requiring less than 1 μL of sample volume to achieve a pg/mL level limit of detection (LOD). However, the bead number in each measurement was not the same, causing an unstable coefficient of variation (CV) in the calibration curve. Here, we investigated whether a fixed number of beads in this bead-based digital microfluidic immunoassay could provide more stable results. First, the bead screening chips were developed to extract exactly 100, 49, and 25 magnetic beads with diameters of less than 6 μm. Then, four calibration curves were established. One calibration curve was constructed by using varying bead numbers (50-160) in the process. The other three calibration curves used a fixed number of beads, (100, 49, and 25). The results indicated that the CVs for a fixed number of beads were evidently smaller than the CVs for varying bead numbers, especially in the range of 1 pg/mL to 100 pg/mL, where the CVs for 100 beads were less than 10%. Furthermore, the calculated LOD, based on the composite calibration curves, could be reduced by three orders, from 3.0 pg/mL (for the unfixed bead number) to 0.0287 pg/mL (for 100 beads). However, when the bead numbers were too high (more than 500) or too low (25 or fewer), the bead manipulation for aggregation became more difficult in the magnetic-beads-based digital microfluidic immunoassay chip.

Indexed as

Immunomagnetic SeparationMicrofluidicsImmunoassayImmunologic TestsMagnetic Phenomenacoefficient of variationdroplet-based microfluidicsimmunoassaymagnetic beads

Identifiers

PMID35624641
PMCPMC9138409
OpenAlexW4280605946

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.