Evidence map›Paper›PMID 35624580›Full record

ArticleBiosensors2022

Scalable Functionalization of Polyaniline-Grafted rGO Field-Effect Transistors for a Highly Sensitive Enzymatic Acetylcholine Biosensor.

Dongsung Park, Dongtak Lee, Hye Jin Kim, Dae Sung Yoon, Kyo Seon Hwang

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Dongsung ParkSchool of Biomedical Engineering, Korea University, Seoul 02841, Korea.
Dongtak LeeSchool of Biomedical Engineering, Korea University, Seoul 02841, Korea.
Hye Jin KimInstitute of Chemical Process (ICP), Seoul National University (SNU), Seoul 08826, Korea.ORCID 0000-0001-7070-4204
Dae Sung YoonSchool of Biomedical Engineering, Korea University, Seoul 02841, Korea.
Kyo Seon HwangDepartment of Clinical Pharmacology and Therapeutics, College of Medicine, Kyung Hee University, Seoul 02447, Korea.ORCID 0000-0003-3590-2074
Korea University · KRKyung Hee University · KRSeoul National University · KR

Funding

Korea Health Industry Development Institute HU21C0053National Research Foundation of Korea NRF-2018M3C1B7020722National Research Foundation of Korea NRF-2021R1A2C2004760
6 · The paper itself

Abstract

For decades, acetylcholine (Ach) has been considered a critical biomarker for several degenerative brain diseases, including Alzheimer's, Parkinson's disease, Huntington's disease, and schizophrenia. Here, we propose a wafer-scale fabrication of polyaniline (PAni)-grafted graphene-based field-effect transistors (PGFET) and their biosensing applications for highly sensitive and reliable real-time monitoring of Ach in flow configuration. The grafted PAni provides suitable electrostatic binding sites for enzyme immobilization and enhances the pH sensitivity (2.68%/pH), compared to that of bare graphene-FET (1.81%/pH) for a pH range of 3-9 without any pH-hysteresis. We further evaluated the PGFET's sensing performance for Ach detection with a limit of detection at the nanomolar level and significantly improved sensitivity (~103%) in the concentration range of 108 nM to 2 mM. Moreover, the PGFET exhibits excellent selectivity against various interferences, including glucose, ascorbic acid, and neurotransmitters dopamine and serotonin. Finally, we investigated the effects of an inhibitor (rivastigmine) on the AchE activity of the PGFET. From the results, we demonstrated that the PGFET has great potential as a real-time drug-screening platform by monitoring the inhibitory effects on enzymatic activity.

Indexed as

Biosensing TechniquesGraphiteAcetylcholineAniline CompoundsAcetylcholineAniline Compoundsgraphene oxideGraphitepolyanilineacetylcholineacetylcholinesterasedrug screeningfield-effect transistor (FET)pH-sensingpolyanilinereduced graphene oxide

Identifiers

PMID35624580
PMCPMC9138234
OpenAlexW4282922531

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.