Evidence map›Paper›PMID 35618555›Full record

ArticleZeitschrift fur medizinische Physik2022

Intraocular reflectance of the ocular fundus and its impact on increased retinal hazard.

Nicole Fehler, Christian Lingenfelder, Sebastian Kupferschmid, Martin Hessling

Open access · goldAbstract read
In one paragraph

Article in Zeitschrift fur medizinische Physik, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Nicole FehlerInstitute of Medical Engineering and Mechatronics, Ulm University of Applied Sciences, Albert-Einstein-Allee 55, 89081, Ulm, Germany. Electronic address: Nicole.Fehler@thu.de.
Christian LingenfelderPharmpur GmbH, Messerschmittring 33, 86343, Koenigsbrunn, Germany.
Sebastian KupferschmidClinic of Ophthalmology, Bundeswehrkrankenhaus Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany.
Martin HesslingInstitute of Medical Engineering and Mechatronics, Ulm University of Applied Sciences, Albert-Einstein-Allee 55, 89081, Ulm, Germany.
Technische Hochschule Ulm · DEBundeswehrkrankenhaus · DEMesser (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeInside the eye light can be reflected multiple times due to light-tissue interactions and the spherical geometry of the eye. Due to these optical properties, a defined retinal area is not only illuminated by direct light but also by indirect, reflected light from the inner side of the eyewall. During illumination for ophthalmic surgery, this could lead to an unintended increase in intraocular retinal irradiance, which was already discussed in previous studies but without a detailed consideration of spectral differences and a potential influence of pigmentation. In this study this effect is investigated wavelength-dependent to see if different wavelengths lead to different increase in irradiance, with a special focus on the raise in photochemical and thermal hazard to the retina. It is also examined whether this effect is dependent on the pigmentation of the eye.

methodsThe reflectance properties of either less or highly pigmented porcine eyes are measured in the wavelength range between 350 and 1100nm with an integrating sphere and a spectrometer. With these reflectance spectra the wavelength-dependent Sphere Multiplier M of porcine eyes can be calculated, which represents the increase of radiance due to multiple reflections inside a sphere compared to a planar diffuser of the same size. Based on measurements of the emitted irradiance of ophthalmic illumination fibers the increase in photochemical and thermal retinal hazard due to these multiple reflections is calculated for eyes with small and high amounts of pigmentation.

resultsThe reflectance of the inner eyewall in the range between 350 and 1100nm is significantly higher for eyes with low pigmentation (between 4.90% and 37.44% reflectance) in comparison to eyes with a high amount of pigmentation (between 4.30% and 28.88% reflectance). The Sphere Multiplier for the inner side of the eyewall (sclera, choroid and retina) ranges between 1.13 and 1.59 and between 1.13 and 1.48 for eyes with low and high pigmentation, respectively, in the range between 350 and 1100nm. The reflectance, as well as the Sphere Multiplier, is strongly wavelength-dependent due to the absorption spectra of melanin and hemoglobin, which are located in the eye. With increasing wavelength, the reflection properties and the Sphere Multiplier also increases. With this, the photochemical retinal hazard of highly pigmented eyes increases by (14.11± 0.09)% and of lightly pigmented eyes by (16.75±0.35)% compared to if the reflection properties are not considered. The thermal retinal hazard increases by (14.30±0.07)% for highly pigmented eyes and by (19.65±0.17)% for low pigmented eyes.

conclusionThis study demonstrates that the anatomy and pigmentation of the eye plays an important role for the reflectance properties of the eye and for the photochemical and thermal hazard to the retina.

Indexed as

LightingRetinaAnimalsFundus OculiScleraSwineIntraocular illuminationPhotochemical hazardPigmentationReflectanceRetinal hazardThermal hazard

Identifiers

PMID35618555
PMCPMC9948856
OpenAlexW4281381193

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.