Evidence map›Paper›PMID 35616923›Full record

ArticleTranslational vision science & technology2022

Improving Visual Field Forecasting by Correcting for the Effects of Poor Visual Field Reliability.

Gabriel A Villasana, Chris Bradley, Tobias Elze, Jonathan S Myers, Louis Pasquale, C Gustavo De Moraes, Sarah Wellik, Michael V Boland, Pradeep Ramulu, Greg Hager and 2 more

Abstract read
In one paragraph

Article in Translational vision science & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Gabriel A VillasanaMalone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD, USA.
Chris BradleyWilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Tobias ElzeMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA.
Jonathan S MyersWills Eye Hospital, Glaucoma Research Center, Philadelphia, PA, USA.
Louis PasqualeIcahn School of Medicine at Mount Sinai, New York, NY, USA.
C Gustavo De MoraesColumbia University Irving Medical Center, New York, NY, USA.
Sarah WellikBascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA.
Michael V BolandMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA.
Pradeep RamuluWilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Greg HagerMalone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD, USA.
Mathias UnberathMalone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD, USA.
Jithin YohannanMalone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD, USA.

Funding

VISION RESEARCHP30EY003790 · NEI · SCHEPENS EYE RESEARCH INSTITUTE · PI Patricia Ann D'Amore · 1985 to 2026
$25.5M
Personalizing Glaucoma Diagnosis by Disease Specific Patterns and Individual Eye AnatomyR01EY030575 · NEI · SCHEPENS EYE RESEARCH INSTITUTE · PI ELZE, TOBIAS · 2019 to 2023
$2.4M
A Comprehensive Strategy to Detect Glaucoma Worsening Earlier and With Fewer TestsK23EY032204 · NEI · JOHNS HOPKINS UNIVERSITY · PI YOHANNAN, JITHIN · 2021 to 2025
$956k
NEI NIH HHS K23 EY032204NEI NIH HHS P30 EY003790NEI NIH HHS R01 EY030575
6 · The paper itself

Abstract

Purpose: The purpose of this study was to accurately forecast future reliable visual field (VF) mean deviation (MD) values by correcting for poor reliability. Methods: Four linear regression techniques (standard, unfiltered, corrected, and weighted) were fit to VF data from 5939 eyes with a final reliable VF. For each eye, all VFs, except the final one, were used to fit the models. Then, the difference between the final VF MD value and each model's estimate for the final VF MD value was used to calculate model error. We aggregated the error for each model across all eyes to compare model performance. The results were further broken down into eye-level reliability subgroups to track performance as reliability levels fluctuate. Results: The standard method, used in the Humphrey Field Analyzer (HFA), was the worst performing model with an average residual that was 0.69 dB higher than the average from the unfiltered method, and 0.79 dB higher than that of the weighted and corrected methods. The weighted method was the best performing model, beating the standard model by as much as 1.75 dB in the 40% to 50% eye-level reliability subgroup. However, its average 95% prediction interval was relatively large at 7.67 dB. Conclusions: Including all VFs in the trend estimation has more predictive power for future reliable VFs than excluding unreliable VFs. Correcting for VF reliability further improves model accuracy. Translational Relevance: The VF correction methods described in this paper may allow clinicians to catch VF worsening at an earlier stage.

Indexed as

GlaucomaVisual FieldsHumansRegression AnalysisReproducibility of ResultsVisual Field Tests

Identifiers

PMID35616923
PMCPMC9145029

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.