Evidence map›Paper›PMID 35615977›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2022

Interventional Microbubble Enhanced Sonothrombolysis on Left Ventricular Assist Devices.

Xiaobing Zheng, Yunfan Pan, Yuan Zhang, Kuilin Meng, Jianye Zhou, Xin Wang, Yongchun Cui, Jiang Li, Yongjian Li, Haosheng Chen

Open access · goldAbstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Magnetic Microrobots as a Platform for Cell Clean Up.... International Conference on Manipulation Automation and Robotics at Small Scales (MARSS). International Conference on Manipulation Automation and Robotics at Small Scales · 2023
    Article
  7. Article
  8. Interventional Microbubble Enhanced Sonothrombolysis on Left Ventricular Assist Devices.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Xiaobing ZhengState Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China.ORCID 0000-0001-9866-307X
Yunfan PanState Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China.
Yuan ZhangSchool of Mechanical Engineering, University of Science and Technology Beijing, Beijing, 100083, China.
Kuilin MengState Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China.
Jianye ZhouAnimal Experiment Center, Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing, 100037, China.
Xin WangAnimal Experiment Center, Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing, 100037, China.
Yongchun CuiAnimal Experiment Center, Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing, 100037, China.
Jiang LiSchool of Mechanical Engineering, University of Science and Technology Beijing, Beijing, 100083, China.
Yongjian LiState Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China.
Haosheng ChenState Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China.ORCID 0000-0002-1134-0989
Tsinghua University · CNChinese Academy of Medical Sciences & Peking Union Medical College · CNUniversity of Science and Technology Beijing · CN

Funding

National Key R&D Program of China 2018YFE0114900National Natural Science Foundation of China for Distinguished Young Scholars 52025051
6 · The paper itself

Abstract

The left ventricular assist device (LVAD) is often used in the treatment of heart failure. However, 4% to 9% implanted LVAD will have thrombosis problem in one year, which is fatal to the patient's life. In this work, an interventional sonothrombolysis (IST) method is developed to realize the thrombolysis on LVAD. A pair of ultrasound transducer rings is installed on the shell of LVAD, and drug-loaded microbubbles are injected into the LVAD through the interventional method. The microbubbles are adhere on the thrombus with the coated thrombus-targeted drugs, and the thrombolytic drugs carried by the bubbles are brought into the thrombus by the cavitation of bubbles under the ultrasound. In a proof-of-concept experiment in a live sheep model, the thrombus on LVAD is dissolved in 30 min, without damages on LVADs and organs. This IST exhibits to be more efficient and safer compared with other thrombolysis methods on LVAD.

Indexed as

Heart-Assist DevicesHeart FailureThrombosisAnimalsFibrinolytic AgentsMicrobubblesSheepFibrinolytic Agentsinterventional therapyLVADmicrobubblethrombolysisultrasound

Identifiers

PMID35615977
PMCPMC9313509
OpenAlexW4281557074

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.