Evidence map›Paper›PMID 35615432›Full record

ArticleHeliyon2022

Biomechanical analysis of sheep oesophagus subjected to biaxial testing including hyperelastic constitutive model fitting.

Harry Ngwangwa, Thanyani Pandelani, Makhosasana Msibi, Israel Mabuda, Letlhogonolo Semakane, Fulufhelo Nemavhola

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
0.7field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Harry NgwangwaUnisa Biomedical Engineering Research Group, Department of Mechanical Engineering, School of Engineering, College of Science Engineering and Technology, University of South Africa, Pretoria, 0001, South Africa.
Thanyani PandelaniUnisa Biomedical Engineering Research Group, Department of Mechanical Engineering, School of Engineering, College of Science Engineering and Technology, University of South Africa, Pretoria, 0001, South Africa.
Makhosasana MsibiUnisa Biomedical Engineering Research Group, Department of Mechanical Engineering, School of Engineering, College of Science Engineering and Technology, University of South Africa, Pretoria, 0001, South Africa.
Israel MabudaUnisa Biomedical Engineering Research Group, Department of Mechanical Engineering, School of Engineering, College of Science Engineering and Technology, University of South Africa, Pretoria, 0001, South Africa.
Letlhogonolo SemakaneUnisa Biomedical Engineering Research Group, Department of Mechanical Engineering, School of Engineering, College of Science Engineering and Technology, University of South Africa, Pretoria, 0001, South Africa.
Fulufhelo NemavholaUnisa Biomedical Engineering Research Group, Department of Mechanical Engineering, School of Engineering, College of Science Engineering and Technology, University of South Africa, Pretoria, 0001, South Africa.
University of South Africa · ZA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High quality computational model of soft tissues is a function of accurate and reliable mechanical properties. Hyperelastic constitutive models are normally utilised in developing reliable computational models. Therefore, section of proper and reliable constitutive models for soft tissue is critical. This work presents the biomechanical properties of oesophagus subjected to biaxial mechanical tensile test. Additionally, six hyperelastic constitutive models commonly used for modelling behaviour of soft tissues were selected. The experimental data were then fitted on Fung, Choi-Vito, Holzapfel (2000), Holzapfel (2005), Polynomial (Anisotropic) and Four-Fiber Family hyperelastic constitutive models. The sheep oesophagus subjected to equi-biaxial tension has exhibited different stress magnitude in both longitudinal and circumferential directions. There is significant difference between circumferential and longitudinal stresses (p = 0.0034). The average circumferential and longitudinal stresses are recorded to be 82.87 ± 30.36 kPa and 41.42 ± 32.02 kPa, respectively (p = 0.0034). Between six hyperelastic constitutive models, it was observed that Four-Fiber model has produced better fit when compared to others. After fitting biaxial mechanical properties of oesophagus, it was found that the Four-fiber family hyperelastic constitutive model would best fit.

Indexed as

Biomechanical properties of oesophagusHyperelastic constitutive modelSoft tissue mechanics

Identifiers

PMID35615432
PMCPMC9124710
OpenAlexW4229038287

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.