ArticleThoracic cancer2022
Puncture frequency predicts pneumothorax in preoperative computed tomography-guided lung nodule localization for video-assisted thoracoscopic surgery.
Article in Thoracic cancer, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07300072 (Pneumothorax Risk and Pleural-Depth-Trimmed Hookwire), which is not on this map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Pneumothorax Risk and Pleural-Depth-Trimmed Hookwire: A Retrospective Cohort Study With Propensity Score Matching in Preoperative CT-Guided Lung Nodule Localization
Who cites it
12 citing papers in PubMed, 8 citations in OpenAlex.
- Article
- Impact of Technical Standardization on Pneumothorax and Chest Tube Insertion Rates: A Retrospective Learning Curve Analysis of CT-Guided Lung Biopsies.Journal of clinical medicine · 2025Article
- A nomogram model for predicting pneumothorax after CT-guided localization of pulmonary nodules using autologous blood and methylene blue.Journal of thoracic disease · 2025Article
- Preoperative localization of pulmonary nodules: virtual bronchoscopic navigation vs a 4‑hook localization needle.Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques · 2025Article
- Comparison of laser-guided technology and conventional manual percutaneous lung biopsy: a single-center retrospective study.Journal of thoracic disease · 2025Article
- Rapid Path Planning Algorithm for Percutaneous Rigid Needle Biopsy Based on Optical Illumination Principles.Sensors (Basel, Switzerland) · 2025Article
- Risk Factors for Pleural Reaction in CT-Guided Percutaneous Lung Nodule Localization: A Single-Center Retrospective Study.Therapeutics and clinical risk management · 2025Article
- Optimizing Precision: A Trajectory Tract Reference Approach to Minimize Complications in CT-Guided Transthoracic Core Biopsy.Diagnostics (Basel, Switzerland) · 2024Article
- Enhancing precision in lung tumor ablation through innovations in CT-guided technique and angle control.Thoracic cancer · 2024Article
- Complications during CT-Guided Lung Nodule Localization: Impact of Needle Insertion Depth and Patient Characteristics.Diagnostics (Basel, Switzerland) · 2023Article
- Safety and efficacy of microwave ablation for lung cancer adjacent to the interlobar fissure.Thoracic cancer · 2022Article
- Puncture frequency predicts pneumothorax in preoperative computed tomography-guided lung nodule localization for video-assisted thoracoscopic surgery.Thoracic cancer · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIatrogenic pneumothorax is the most frequent complication in preoperative CT-guided localization (POCTGL) of lung nodules. We aimed to determine the predictive factors of iatrogenic pneumothorax.
methodsWe retrospectively analyzed data of consecutive POCTGL procedures in patients who received video-assisted thoracoscopic surgery (VATS) at our hospital between May 2015 and October 2019. All of our patients utilized laser angle guide assembly to aid in the localization procedures.
resultsIn 610 consecutive POCTGL procedures, 40 (6.6%) patients developed iatrogenic pneumothorax, and complications occurred in 8.5%. Univariate analyses revealed that puncture frequency, male gender, puncture depth, left decubitus position, and nodule near fissure were factors associated with pneumothorax, while multivariate analysis showed that only male gender (odds ratio 3.58, p = 0.012) and puncture frequency (odds ratio 2.39/time, p = 0.0004) determined development of pneumothorax. Further collective analysis on puncture frequency revealed that tumor in a difficult zone (1.33 ± 0.71 vs. 1.19 ± 0.45, p = 0.002), especially adjacent to the mediastinum (1.41 ± 0.75 vs. 1.21 ± 0.52, p = 0.002), angle difference of plan-to-practice (r = 0.209, p = < 0.001), depth to skin (r = 0.152, p < 0.001), and depth to pleura (r = 0.164, p < 0.001) were factors related to increased puncture frequency in univariate analyses. Only angle difference of plan-to-practice was associated in multivariate analysis (odds ratio: 1.158, p = 0.008).
conclusionsPuncture frequency was the key factor in the development of iatrogenic pneumothorax from POCTGL. Other associated factors, especially angle difference, may have affected the puncture frequency and subsequently have some influence on the incidence of iatrogenic pneumothorax.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.