Evidence map›Paper›PMID 35613881›Full record

ArticleNeurologia medico-chirurgica2022

Primary Experiences with Robot-assisted Navigation-based Frameless Stereo-electroencephalography: Higher Accuracy than Neuronavigation-guided Manual Adjustment.

Yuichiro Kojima, Takehiro Uda, Toshiyuki Kawashima, Saya Koh, Masato Hattori, Yuki Mito, Noritsugu Kunihiro, Shohei Ikeda, Ryoko Umaba, Takeo Goto

Abstract read
In one paragraph

Article in Neurologia medico-chirurgica, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Usefulness of Robotic Stereotactic Assistance (ROSANeurologia medico-chirurgica · 2024
    Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Image-guided biopsy of intracranial lesions in children, with a small robotic device: a case series.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2024
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yuichiro KojimaDepartment of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine.
Takehiro UdaDepartment of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine.
Toshiyuki KawashimaDepartment of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine.
Saya KohDepartment of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine.
Masato HattoriDepartment of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine.
Yuki MitoDepartment of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine.
Noritsugu KunihiroDepartment of Pediatric Neurosurgery, Osaka City General Hospital.
Shohei IkedaDepartment of Pediatric Neurosurgery, Osaka City General Hospital.
Ryoko UmabaDepartment of Pediatric Neurosurgery, Osaka City General Hospital.
Takeo GotoDepartment of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of robot-assisted frameless stereotactic electroencephalography (SEEG) is becoming more common. Among available robotic arms, Stealth Autoguide (SA) (Medtronic, Minneapolis, MN, USA) functions as an optional instrument of the neuronavigation system. The aims of this study were to present our primary experiences with SEEG using SA and to compare the accuracy of implantation between SA and navigation-guided manual adjustment (MA). Seventeen electrodes from two patients who underwent SEEG with SA and 18 electrodes from four patients with MA were retrospectively reviewed. We measured the distance between the planned location and the actual location at entry (De) and the target (Dt) in each electrode. The length of the trajectory did not show a strong correlation with Dt in SA (Pearson's correlation coefficient [r] = 0.099, p = 0.706) or MA (r = 0.233, p = 0.351). De and Dt in SA were shorter than those in MA (1.99 ± 0.90 vs 4.29 ± 1.92 mm, p = 0.0002; 3.59 ± 2.22 vs 5.12 ± 1.40 mm, p = 0.0065, respectively). SA offered higher accuracy than MA both at entry and target. Surgical times per electrode were 38.9 and 32 min in the two patients with SA and ranged from 51.6 to 88.5 min in the four patients with MA. During the implantation period of 10.3 ± 3.6 days, no patients experienced any complications.

Indexed as

NeuronavigationRoboticsElectrodes, ImplantedElectroencephalographyHumansRetrospective StudiesStereotaxic TechniquesAutoguideepilepsy surgeryneuronavigationrobot armSEEG

Identifiers

PMID35613881
PMCPMC9464478

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.