Evidence map›Paper›PMID 35613784›Full record

ArticleBMJ open2022

Automatic vein measurement by ultrasonography to prevent peripheral intravenous catheter failure for clinical practice using artificial intelligence: development and evaluation study of an automatic detection method based on deep learning.

Toshiaki Takahashi, Gojiro Nakagami, Ryoko Murayama, Mari Abe-Doi, Masaru Matsumoto, Hiromi Sanada

Open access · goldAbstract read
In one paragraph

Article in BMJ open, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
3.2field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Toshiaki TakahashiDepartment of Gerontological Nursing/Wound Care Management, The University of Tokyo, Tokyo, Japan.ORCID 0000-0001-5724-4784
Gojiro NakagamiDepartment of Gerontological Nursing/Wound Care Management, The University of Tokyo, Tokyo, Japan.
Ryoko MurayamaResearch Center for Implementation Nursing Science Initiative, Reseach Promotion Headquarters, Fujita Health University, Aichi, Japan.
Mari Abe-DoiDepartment of Gerontological Nursing/Wound Care Management, The University of Tokyo, Tokyo, Japan.
Masaru MatsumotoIshikawa Prefectural Nursing University, Ishikawa, Japan.
Hiromi SanadaIshikawa Prefectural Nursing University, Ishikawa, Japan hsanada@g.ecc.u-tokyo.ac.jp.
The University of Tokyo · JPIshikawa Prefectural Nursing University · JPFujita Health University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesComplications due to peripheral intravenous catheters (PIVC) can be assessed using ultrasound imaging; however, it is not routinely conducted due to the need for training in image reading techniques. This study aimed to develop and validate a system that automatically measures blood vessel diameters on ultrasound images using artificial intelligence (AI) and provide recommendations for selecting an implantation site.

designPilot study.

settingThe University of Tokyo Hospital, Japan. PRIMARY AND SECONDARY OUTCOME MEASURES: First, based on previous studies, the vessel diameter was calculated as the mean value of the maximum long diameter plus the maximum short diameter orthogonal to it. Second, the size of the PIVC to be recommended was evaluated based on previous studies. For the development and validation of an automatic detection tool, we used a fully convoluted network for automatic estimation of vein location and diameter. The agreement between manually generated correct data and automatically estimated data was assessed using Pearson's product correlation coefficient, systematic error was identified using the Bland-Altman plot, and agreement between catheter sizes recommended by the research nurse and those recommended by the system was evaluated.

resultsThrough supervised machine learning, automated determination was performed using 998 ultrasound images, of which 739 and 259 were used as the training and test data set, respectively. There were 24 false-negatives indicating no arteries detected and 178 true-positives indicating correct detection. Correlation of the results between the system and the nurse was calculated from the 178 images detected (r=0.843); no systematic error was identified. The agreement between the sizes of the PIVC recommended by the research nurse and the system was 70.2%; 7% were underestimated and 21.9% were overestimated.

conclusionsOur automated AI-based image processing system may aid nurses in assessing peripheral veins using ultrasound images for catheterisation; however, further studies are still warranted.t.

Indexed as

Artificial IntelligenceDeep LearningCathetersHumansPilot ProjectsUltrasonographyeducation & training (see medical education & training)information technologyultrasonography

Identifiers

PMID35613784
PMCPMC9174762
OpenAlexW4281476742

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked