Evidence map›Paper›PMID 35611603›Full record

ArticleMedical physics2022

Radiation shielding assessment of high-energy proton imaging at a proton therapy facility.

Scott N Penfold

Open access · hybridAbstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author at 1 institution in 1 country.

Scott N PenfoldAustralian Bragg Centre for Proton Therapy and Research, South Australian Health and Medical Research Institute, Adelaide, South Australia, Australia.
University of Adelaide · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProton imaging makes use of high-energy, low-intensity proton beams that fully traverse the patient and has been suggested to reduce range uncertainty in proton therapy. Upright patient positioning with proton imaging is being considered for a fixed beam room of a new proton therapy facility currently under construction. Considering that the yield and energy spectrum of secondary radiation from high-energy proton beams is proton beam energy dependent, an assessment of radiation shielding at the energies required for proton imaging should be performed prior to use. Furthermore, NCRP 144 recommends that pion production be considered for proton energies greater than 300 MeV, which are not typically utilized for proton therapy but may be required for proton imaging. PURPOSE: The purpose of this work was to determine whether proton treatment and imaging with an upright patient positioning system on a fixed beamline were acceptable from a radiation shielding perspective. This is the first report on radiation shielding assessment of proton imaging applications and includes consideration of pion production at the proton beam energy of 330 MeV.

methodsThe Geant4 Monte Carlo toolkit was used for the radiation shielding assessment. The calculations consisted of the generation of secondary particle phase-space files by simulating the passage of high-energy proton beams in two target materials, and subsequent simulation of the secondary particles in the proton therapy facility geometry. Particle fluence was converted to operational and protection radiation safety quantities with a custom python script for assessment of instantaneous and annual doses, respectively.

resultsThe total yields of pions from a 330-MeV proton beam were many orders of magnitude less than that of neutrons and photons. Three-dimensional maps of ambient dose rate for a 330-MeV proton beam showed doses arising from secondary neutrons and photons far exceed those arising from pion production. Incorporating representative annual workloads into the calculation demonstrated that proton imaging doses outside the shielded area were negligible compared to those arising from proton therapy.

conclusionsPion production has a negligible impact on the radiation shielding of proton imaging at 330 MeV relative to neutron and photon production. Radiation shielding designed for proton therapy is adequate for high-energy proton imaging applications.

Indexed as

Proton TherapyRadiation ProtectionHumansMonte Carlo MethodNeutronsProtonsRadiation DosageRadiometryProtonsproton imagingproton therapyproton therapy shieldingradiation safety

Identifiers

PMID35611603
PMCPMC9545135
OpenAlexW4281478114

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.