Evidence map›Paper›PMID 35610284›Full record

ArticleScientific reports2022

Rapid measurement of thoracolumbar kyphosis with the integrated inclinometer of a smartphone: a validity and reliability study.

Tianji Huang, Zenghui Zhao, Lin Wang, Chao Zhang, Runhan Zhao, Chuang Xiong, Weiyang Zhong, Xiaoji Luo

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Tianji HuangDepartment of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People's Republic of China.
Zenghui ZhaoDepartment of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People's Republic of China.
Lin WangDepartment of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People's Republic of China.
Chao ZhangDepartment of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People's Republic of China.
Runhan ZhaoDepartment of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People's Republic of China.
Chuang XiongDepartment of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People's Republic of China.
Weiyang Zhong *Department of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People's Republic of China. zhongweiyang@hospital.cqmu.edu.cn.
Xiaoji Luo *Department of Orthopedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People's Republic of China. cy2982@163.com.
First Affiliated Hospital of Chongqing Medical University · CNChongqing Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of this study was to evaluate the accuracy, reliability, and time requirements of two methods for measuring thoracolumbar kyphosis: a conventional method using a picture archiving and communication system (PACS) and this new method using the integrated inclinometer of a smartphone. The thoracolumbar kyphotic angles of one hundred consecutive patients were measured by a PACS and this novel smartphone method. The measured angles were analysed by multiple statistical methods, and the two measurement tools were compared in terms of accuracy, reliability, and time requirements. The mean result of thoracolumbar kyphosis measured by the PACS was 21.43 ± 12.96°, and the mean value measured by the smartphone was 21.03 ± 13.01°. A Bland-Altman plot for these two methods showed a mean difference of 0.4°, with the limits of agreement being -2.4° and 3.2°. One-way ANOVA showed no significant difference (F = 0.080, P = 0.999) among measurements by different observers and different methods. The intraclass correlation coefficients (ICCs) of the mean values of four repeated measurements of thoracolumbar kyphosis between these two methods were 0.997 (0.995-0.998), revealing that the two methods were highly correlated. The ICC results showed that the concordance between these two methods was very good for all measurements of thoracolumbar kyphosis, and the inter- and intra-observer reliability of the novel smartphone method were very good. The PACS method (36.95 ± 0.98 s) took significantly longer than the smartphone method (17.68 ± 0.97 s) when compared by an independent-samples t test (P = 0.000). This new method using the integrated inclinometer of a smartphone has satisfactory validity and reliability compared to the PACS method. Additionally, the new method took significantly less time than the PACS method. Measuring with a smartphone is more convenient than using a PACS, which is always rooted in a full-sized computer. In summary, this new method using the integrated inclinometer of a smartphone is rapid, convenient, accurate and reliable when measuring thoracolumbar kyphosis in osteoporotic vertebral compression fracture (OVCF) patients.

Indexed as

Fractures, CompressionKyphosisSpinal FracturesHumansReproducibility of ResultsSmartphone

Identifiers

PMID35610284
PMCPMC9130239
OpenAlexW4281395047

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.