Evidence map›Paper›PMID 35609974›Full record

ArticleJournal of neurointerventional surgery2023

Coating (Coating to Optimize Aneurysm Treatment in the New Flow Diverter Generation) study. The first randomized controlled trial evaluating a coated flow diverter (p64 MW HPC): study design.

Laurent Pierot, Saleh Lamin, Xavier Barreau, Ansgar Berlis, Elisa Ciceri, José E Cohen, Vincent Costalat, Omer F Eker, Hans Henkes, Markus Holtmannspötter and 7 more

Registry-linked trialOpen access · hybridAbstract readClinical Trial Protocol
In one paragraph

Article in Journal of neurointerventional surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04870047 (Coating to Optimize Aneurysm Treatment In The New Flow Diverter Generation), which is not on this map. Cited by 16 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 2 pooled it
3.7field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04870047 naactive not recruitingnot on this map

Coating to Optimize Aneurysm Treatment In The New Flow Diverter Generation

TypeinterventionalSponsorPhenox GmbHRan2021 to 2025Enrolled171ConditionsIntracranial AneurysmArmsEndovascular treatment of unruptured aneurysms with p64 MW HPC Flow Modulation Device
3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 2 syntheses or guidelines pooled it, 31 citations in OpenAlex.

  1. The safety profile of single antiplatelet therapy with flow diverters: Systematic review and meta-analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Pooled it
  2. Short to mid-term outcomes of flow re-direction endoluminal device X (FREDDiagnostic and interventional radiology (Ankara, Turkey) · 2026
    Pooled it
  3. Review
  4. Article
  5. Flow diverter surface modifications for aneurysm treatment: A review of the mechanisms and data behind existing technologies.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Review
  6. Article
  7. Impact of surface coating on postinterventional DWI lesions: A comparative analysis of coated and uncoated FRED and DERIVO flow-diverters in the treatment of intracranial aneurysms.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  8. The use of FD-HPC in Ruptured and Unruptured Aneurysms, the Italian Dataset (RUAID): Preliminary results on feasibility and safety.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  9. Article
  10. Article
  11. Multicenter study of HPC coated p48 and p64 flow diverters for treatment of intracranial aneurysms under dual antiplatelet therapy.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors at 15 institutions in 6 countries.

Laurent PierotDepartment of Neuroradiology, Hôpital Maison Blanche, CHU Reims, Université Reims Champagne Ardenne, Reims, France lpierot@gmail.com.ORCID http://orcid.org/0000-0002-2523-4909
Saleh LaminDepartment of Interventional Neuroradiology, University Hospitals Birmingham NHS Foundation Trust, Birmingham, Birmingham, UK.
Xavier BarreauDepartment of Neuroradiology, CHU Bordeaux GH Pellegrin, Bordeaux, Aquitaine, France.
Ansgar BerlisDepartment of Diagnostic and Interventional Neuroradiology, Klinikum Augsburg, Augsburg, Bayern, Germany.
Elisa CiceriDepartment of Neuroradiology, Fondazione IRCSS Instituto Neurologico Carlo Besta, Milano, Lombardia, Italy.
José E CohenDepartment of Neurosurgery and Radiology, Hadassah Hebrew University, University Medcal Centers, Jerusalem, Jerusalem, Israel.
Vincent CostalatDepartment of Neuroradiology, CHU Montpellier, Hôpital Gui de Chauliac, Montpellier, France.
Omer F EkerDepartment of Neuroradiology, CHU Lyon, Lyon, Auvergne-Rhône-Alpes, France.
Hans HenkesNeuroradiological Clinic, Klinikum Stuttgart, Stuttgart, Baden-Württemberg, Germany.
Markus HoltmannspötterDepartment of Neuroradiology, Nuremberg Hospital, South Campus, Paracelsus Medical University, Nuremberg, Bayern, Germany.
Anne-Christine JanuelDepartment of Neuroradiology, CHU Toulouse, Toulouse, Occitanie, France.
Peter KestonDepartment of Neuroradiology, Royal Infirmary of Edinburgh, Edinburgh, Edinburgh, UK.
Joachim KlischDepartment of Neuroradiology, HELIOS Klinikum Erfurt, Erfurt, Thüringen, Germany.
Marios-Nikos PsychogiosDepartment of Neuroradiology, University Hospital Basel, Basel, BS, Switzerland.
Luca ValvassoriDepartment of Neuroradiology, San Carlo Borromeo Hospital, Milano, Lombardia, Italy.
Christophe CognardDepartment of Neuroradiology, CHU Toulouse, Toulouse, Occitanie, France.
Laurent SpelleNEURI Interventional Neuroradiology, APHP, Paris, Île-de-France, France.ORCID http://orcid.org/0000-0002-6748-8528
Centre Hospitalier Universitaire de Toulouse · FRCentre Hospitalier Universitaire de Reims · FREdinburgh Royal Infirmary · GBFondazione IRCCS Istituto Neurologico Carlo Besta · ITHadassah Medical Center · ILHelios Klinikum Erfurt · DEHôpital Gui de Chauliac · FRHôpital Pellegrin · FRKlinikum Stuttgart · DENuremberg Hospital · DEOspedale San Carlo · ITUniversité Paris-Saclay · FRUniversity Hospital Augsburg · DEUniversity Hospital of Basel · CHUniversity Hospitals Birmingham NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDue to its high efficacy, flow diversion is increasingly used in the management of unruptured and recanalized aneurysms. Because of the need for perioperative dual antiplatelet treatment (DAPT), flow diversion is not indicated for the treatment of ruptured aneurysms. To overcome this major limitation, surface modification-'coating'-of flow diverters has been developed to reduce platelet aggregation on the implanted device, reduce thromboembolic complications, and facilitate the use of coated flow diverter treatment in patients with single antiplatelet treatment (SAPT). COATING (Coating to Optimize Aneurysm Treatment in the New Flow Diverter Generation) is a prospective, randomized, multicenter trial that aims to determine whether the use of the coated flow diverter p64 MW HPC under SAPT is non-inferior (or even superior) to the use of the bare flow diverter p64 MW under DAPT in relation to thromboembolic and hemorrhagic complications.

methodsPatients with unruptured or recanalized aneurysms for which endovascular treatment with a flow diverter is indicated will be enrolled and randomly assigned on a 1:1 ratio to one of two treatment groups: p64 MW HPC with SAPT or p64 MW with DAPT.

resultsThe primary endpoint is the number of diffusion-weighted imaging lesions visualized via MRI assessed within 48 hours (±24 hours) of the index procedure. Secondary primary endpoints are comparing safety and efficacy in both arms.

conclusionsThis randomized controlled trial is the first to directly compare safety and efficacy of coated flow diverters under SAPT with bare flow diverters under DAPT. TRIAL REGISTRATION NUMBER: http://clinicaltrials.gov/ - NCT04870047.

Indexed as

Endovascular ProceduresIntracranial AneurysmHumansMulticenter Studies as TopicPlatelet Aggregation InhibitorsProspective StudiesRandomized Controlled Trials as TopicRetrospective StudiesStentsTreatment OutcomePlatelet Aggregation InhibitorsAneurysmFlow Diverter

Identifiers

PMID35609974
PMCPMC10314041
OpenAlexW4282926415

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.