ArticleEuropean journal of hospital pharmacy : science and practice2023
Evaluation of the stability of temocillin in elastomeric infusion devices used for outpatient parenteral antimicrobial therapy in accordance with the requirements of the UK NHS Yellow Cover Document.
Article in European journal of hospital pharmacy : science and practice, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.
- Systematic review of room temperature stability of key beta-lactam antibiotics for extended infusions in inpatient settings.European journal of hospital pharmacy : science and practice · 2023Pooled it
- 2026 Updated good practice recommendations for outpatient parenteral antimicrobial therapy (OPAT) in adults and children in the UK.JAC-antimicrobial resistance · 2026Review
- Continuous infusion OPAT via elastomeric pumps: effectiveness, safety, and cost-saving potential in a real-world Italian cohort.Infection · 2026Article
- Delivery of Outpatient Parenteral Antimicrobial Therapy (OPAT) in an Ever-Changing National Health Service (UK): Benefits, Barriers, and Opportunities.Antibiotics (Basel, Switzerland) · 2025Review
- Antibiotic Stability and Feasibility in Elastomeric Infusion Devices for OPAT: A Review of Current Evidence.Journal of clinical medicine · 2025Review
- Current practices and challenges of outpatient parenteral antimicrobial therapy: a narrative review.The Journal of antimicrobial chemotherapy · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 7 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo evaluate the stability of temocillin solution in two elastomeric infusion devices - Easypump II LT 270-27- S and Dosi-Fusor L25915-250D1 for OPAT administration during 14 days of 5°C±3°C fridge storage followed by 24 hour exposure at an in-use temperature of 32°C, when reconstituted with 0.3% citrate buffer at pH7.
methodsStability testing was conducted in accordance with standard protocols in the UK National Health Service Yellow Cover Document (YCD). A stability indicating assay method was applied using a high-performance liquid chromatography (HPLC) system with a photodiode array detector. Low (500 mg/240 mL), intermediate (4000 mg/240 mL) and high (6000 mg/240 mL) temocillin concentrations were tested in triplicate devices with duplicate samples taken at 11 time points during fridge storage and subsequent in-use temperature exposure.
resultThe percentage of temocillin remaining after 14 days of fridge storage was greater than 97% in both devices and at all concentrations tested. During subsequent in-use temperature exposure, a 95% stability limit was achieved for 12 hours except for the high concentration (25 mg/mL) in the Dosi-Fusor device. It met this criterion for only 10 hours - the percent of temocillin remaining at 12 hours was 94.5%. However, for all devices and the doses tested, the degradation of temocillin was <9% at the end of 24 hours in-use temperature exposure.
conclusionTemocillin reconstituted with 0.3% citrate buffer at pH7 in elastomeric infusion devices can be stored in a fridge (2°C-8°C) for 14 days meeting the YCD acceptance criteria. Considering <5% degradation, the current data supports twice daily dosing of temocillin within the OPAT setting. In jurisdictions where a <10% degradation limit is acceptable, once daily dosing with 24-hour continuous infusion may be considered. Temocillin is a useful alternative to other broad-spectrum anti-Gram-negative agents currently utilised in the OPAT setting and supports the wider antimicrobial stewardship agenda.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.