Evidence map›Paper›PMID 35605005›Full record

ArticlePloS one2022

Geometric distortion assessment in 3T MR images used for treatment planning in cranial Stereotactic Radiosurgery and Radiotherapy.

Stefanos Theocharis, Eleftherios P Pappas, Ioannis Seimenis, Panagiotis Kouris, Dimitrios Dellios, Georgios Kollias, Pantelis Karaiskos

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.7field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Stefanos TheocharisMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Eleftherios P PappasMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.ORCID 0000-0003-4030-2241
Ioannis SeimenisMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Panagiotis KourisMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Dimitrios DelliosMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.ORCID 0000-0002-2576-6331
Georgios KolliasMedical Physics and Gamma Knife Department, Hygeia Hospital, Marousi, Greece.
Pantelis KaraiskosMedical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece.ORCID 0000-0002-3665-2989
National and Kapodistrian University of Athens · GRHygeia Hospital · GR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Magnetic Resonance images (MRIs) are employed in brain Stereotactic Radiosurgery and Radiotherapy (SRS/SRT) for target and/or critical organ localization and delineation. However, MRIs are inherently distorted, which also impacts the accuracy of the Magnetic Resonance Imaging/Computed Tomography (MRI/CT) co-registration process. In this phantom-based study, geometric distortion is assessed in 3T T2-weighted images (T2WIs), while the efficacy of an MRI distortion correction technique is also evaluated. A homogeneous polymer gel-filled phantom was CT-imaged before being irradiated with 26 4-mm Gamma Knife shots at predefined locations (reference control points). The irradiated phantom was MRI-scanned at 3T, implementing a T2-weighted protocol suitable for SRS/SRT treatment planning. The centers of mass of all shots were identified in the 3D image space by implementing an iterative localization algorithm and served as the evaluated control points for MRI distortion detection. MRIs and CT images were spatially co-registered using a mutual information algorithm. The inverse transformation matrix was applied to the reference control points and compared with the corresponding MRI-identified ones to evaluate the overall spatial accuracy of the MRI/CT dataset. The mean image distortion correction technique was implemented, and resulting MRI-corrected control points were compared against the corresponding reference ones. For the scanning parameters used, increased MRI distortion (>1mm) was detected at areas distant from the MRI isocenter (>5cm), while median radial distortion was 0.76mm. Detected offsets were slightly higher for the MRI/CT dataset (0.92mm median distortion). The mean image distortion correction improves geometric accuracy, but residual distortion cannot be considered negligible (0.51mm median distortion). For all three datasets studied, a statistically significant positive correlation between detected spatial offsets and their distance from the MRI isocenter was revealed. This work contributes towards the wider adoption of 3T imaging in SRS/SRT treatment planning. The presented methodology can be employed in commissioning and quality assurance programmes of corresponding treatment workflows.

Indexed as

RadiosurgeryMagnetic Resonance ImagingPhantoms, ImagingRadiotherapy Planning, Computer-AssistedTomography, X-Ray Computed

Identifiers

PMID35605005
PMCPMC9126373
OpenAlexW4281287065

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.