ArticleJournal of hand surgery global online2022
Appropriately Matched Fixed-Angle Locking Plates Improve Stability in Volar Distal Radius Fixation.
Article in Journal of hand surgery global online, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- Anatomical Fit of the Volar Locking Plate for Distal Radius and Influence of the Plate Size.Journal of wrist surgery · 2026Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Size options for volar locking plates may provide value for distal radius fixation. We compared excessively narrow plates with plates that were appropriately matched in width for fixation of an multifragmented distal radius fracture model. Methods: Eighteen matched pairs (right and left wrists) of large, cadaveric male distal radii specimens, prepared with a simulated Arbeitsgemeinschaft für Osteosynthesefragen type C-3 distal radius fractures, were tested. One specimen from each matched pair was randomized to receive a plate that was appropriately matched in width to the distal radius. The contralateral limb received a narrow plate, which in all cases was undersized in width. Fixation stability was tested and compared to the contralateral matched specimen. Specimens were preloaded at 50 N for 30 seconds before cyclic loading from 50-250 N at 1 Hz for 5000 cycles then loaded to failure. Results: Loss of fixation under cyclic loading was significantly greater in the specimens fixed with excessively narrow plates compared with plates of appropriate width. When loaded to failure, the plates of appropriate width were stiffer, with higher force at failure and compressive strength than narrow plates. The primary mode of failure was displacement of the distal lunate facet fragment. Conclusions: These findings suggest that optimally matching the volar locking plate width to the radius may provide advantages for stability of the fixation construct and fragment capture. This may be due to reduced stress concentration from the distribution of forces across a larger surface area. Clinical relevance: Optimizing the plate width to the radial width may improve fracture stability and may carry additional importance in comminuted fractures, where narrow plates may not completely capture small bone fragments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.