Evidence map›Paper›PMID 35601190›Full record

ArticleEnvironmental health insights2022

Assessment of Microbiological Quality of Indoor Air at Different Hospital Sites of Dilla University: A Cross-Sectional Study.

Zemachu Ashuro, Kuma Diriba, Abel Afework, Gose Husen Washo, Abriham Shiferaw Areba, Girum G/Meskel Kanno, Habtamu Endashaw Hareru, Abdene Weya Kaso, Mehret Tesfu

Open access · goldAbstract read
In one paragraph

Article in Environmental health insights, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. A review on factors related to patient comfort experience in hospitals.Journal of health, population, and nutrition · 2023
    Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Zemachu AshuroDepartment of Environmental Health, College of Health Science and Medicine, Dilla University, Dilla, Ethiopia.ORCID https://orcid.org/0000-0003-4098-940X
Kuma DiribaDepartment of Medical Laboratory Sciences, College of Health Science and Medicine, Dilla University, Dilla, Ethiopia.
Abel AfeworkDepartment of Infection Prevention and Control, Dilla University Hospital, Dilla, Ethiopia.ORCID https://orcid.org/0000-0002-9828-7446
Gose Husen WashoSchool of Medicine, College of Health Science and Medicine, Dilla University, Dilla, Ethiopia.
Abriham Shiferaw ArebaDepartement of Public Health, College of Medicine and Health Science, Wachemo University, Hossana, Ethiopia.
Girum G/Meskel KannoDepartment of Environmental Health, College of Health Science and Medicine, Dilla University, Dilla, Ethiopia.ORCID https://orcid.org/0000-0001-6689-1983
Habtamu Endashaw HareruSchool of Public Health, College of Health Science and Medicine, Dilla University, Dilla, Ethiopia.ORCID https://orcid.org/0000-0002-0591-0893
Abdene Weya KasoSchool of Public Health, College of Health Science and Medicine, Dilla University, Dilla, Ethiopia.
Mehret TesfuSchool of Public Health, College of Health Science and Medicine, Dilla University, Dilla, Ethiopia.
Dilla University · ETWachemo University

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In both residential and hospital indoor environments, humans can be exposed to airborne microorganisms. The hospital's indoor air may contain a large number of disease-causing agents brought in by patients, staff, students, visitors, ventilation, or the outside. Hospitalized patients are at a higher risk of infection due to confined spaces, crowdedness, and poor infection prevention practices, which can accumulate and create favorable conditions for the growth and multiplication of microorganisms. Therefore, the aim of this study was to evaluate the indoor air bacterial load in Dilla University Hospital, Southern Ethiopia. Methods: An institutional-based cross-sectional study design was used to assess the bacterial load in the indoor air at Dilla University Hospital. To determine the bacterial load, a passive air sampling technique was used. The settle plate method was used to collect data, which involved exposing Petri-dishes filled with blood agar media to the indoor air of the sampled rooms for 60 minutes. Result: A total of 72 indoor air samples were collected once a week for 2 weeks at 14-day intervals from 18 rooms in 8 wards, and samples were collected twice a day in the morning and afternoon. The mean bacterial concentrations ranged from 450 to 1585.83 CFU/m Conclusion: The majority of the wards at Dilla University Hospital had bacterial loads in the air that exceeded WHO guidelines. Overcrowding, high temperatures, inadequate ventilation, improper waste management, and a lack of traffic flow control mechanisms could all contribute to a high concentration of bacteria in the indoor air. To control the introduction of microorganisms by patients, students, caregivers, and visitors, it is critical to regularly monitor indoor air bacterial load and implement infection prevention and control measures.

Indexed as

Bacterial loadhospital wardsindoor air and settling plate

Identifiers

PMID35601190
PMCPMC9121508
OpenAlexW4285196659

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.