Accuracy of segmented measurement of axial length in ultra-high myopia filled with silicone oil using immersion B-scan ultrasonography.

Qing-Hua Yang, Hong-Tao Zhang, Xiao-Qi Li, Bing Chen, Zhao-Hui Li, Yi-Fei Huang, Xin Jin, Ying Zhang, Li-Qiang Wang

Open access · goldAbstract read
In one paragraph

Article in International journal of ophthalmology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 87% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Qing-Hua YangSenior Department of Ophthalmology, the Third Medical Center of PLA General Hospital, Beijing 100039, China.
Hong-Tao ZhangSenior Department of Ophthalmology, the Third Medical Center of PLA General Hospital, Beijing 100039, China.
Xiao-Qi LiSenior Department of Ophthalmology, the Third Medical Center of PLA General Hospital, Beijing 100039, China.
Bing ChenSenior Department of Ophthalmology, the Third Medical Center of PLA General Hospital, Beijing 100039, China.
Zhao-Hui LiSenior Department of Ophthalmology, the Third Medical Center of PLA General Hospital, Beijing 100039, China.
Yi-Fei HuangSenior Department of Ophthalmology, the Third Medical Center of PLA General Hospital, Beijing 100039, China.
Xin JinSenior Department of Ophthalmology, the Third Medical Center of PLA General Hospital, Beijing 100039, China.
Ying ZhangSenior Department of Ophthalmology, the Third Medical Center of PLA General Hospital, Beijing 100039, China.
Li-Qiang WangSenior Department of Ophthalmology, the Third Medical Center of PLA General Hospital, Beijing 100039, China.
Chinese PLA General Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo evaluate the accuracy of segmented measurement of axial length (AL) in high myopia filled with silicone oil by immersion B-scan ultrasonography (immersion B-scan).

methodsFrom June 2016 to June 2020, a total of 67 ultra-high myopia inpatients (67 eyes) who underwent silicone oil removal combined with cataract extraction and intraocular lens (IOL) implantation were retrospectively enrolled. The preoperative axial length (AL) of 31 patients with severe cataract were segmented measured using immersion B-scan (B-scan group) and another 36 patients with mild or moderate cataract were measured using IOLMaster 500 (IOLMaster group). The post-operative ALs in two groups were both measured using IOLMaster 500. The IOL power was calculated with Haigis formula. The differences in ALs between pre- and post-surgery, as well as the postoperative refractive spherical equivalent, absolute refractive error, the prediction deviation of postoperative refraction and best corrected visual acuity (BCVA) were compared.

resultsThe pre- and post-operative ALs were 30.46±1.63 mm (range 28.09-33.51 mm) and 30.42±1.70 mm (range 28.03-33.90 mm) in B-scan group (

conclusionThe segmented measurement of ALs by immersion B-scan shows comparable measurement accuracy with that of IOLMaster 500 in ultra-high myopia patients with severe cataract secondary to silicone oil filling and can obtain an ideal postoperative refractive state.

Indexed as

axial lengthcataracthigh myopiaimmersion B-ultrasoundIOLMastersilicone oil

Identifiers

PMID35601170
PMCPMC9091887
OpenAlexW4285743498

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.