Evidence map›Paper›PMID 35601126›Full record

ArticleJGH open : an open access journal of gastroenterology and hepatology2022

Self-expandable metal stents have longer patency and less cholangitis than inside stents in malignant perihilar biliary obstruction.

Akinobu Koiwai, Morihisa Hirota, Tomofumi Katayama, Ryo Kin, Keita Kawamura, Katsuya Endo, Takayuki Kogure, Atsuko Takasu, Takayoshi Meguro, Kennichi Satoh

Open access · goldAbstract read
In one paragraph

Article in JGH open : an open access journal of gastroenterology and hepatology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 2 pooled it
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 2 syntheses or guidelines pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Akinobu KoiwaiDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.ORCID https://orcid.org/0000-0002-7657-1913
Morihisa HirotaDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.ORCID https://orcid.org/0000-0001-5682-0911
Tomofumi KatayamaDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.
Ryo KinDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.
Keita KawamuraDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.
Katsuya EndoDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.ORCID https://orcid.org/0000-0002-6449-8392
Takayuki KogureDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.
Atsuko TakasuDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.
Takayoshi MeguroDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.
Kennichi SatohDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Sendai City Miyagi Japan.ORCID https://orcid.org/0000-0003-1324-6387
Tohoku Medical and Pharmaceutical University Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aim: Outcomes of an inside stent (IS, a plastic stent placed above the sphincter of Oddi) Methods: Clinical data of patients who underwent biliary drainage for malignant perihilar biliary obstruction with IS or SEMS between April 2016 and September 2021 at our institution were retrospectively examined. Outcomes, including the time to recurrent biliary obstruction (TRBO), survival, and incidence of recurrent biliary obstruction with concomitant cholangitis (RBOC), were retrospectively evaluated. Results: Median TRBO was 280 (95% confidence interval [CI], 110-not available) days in the SEMS group ( Conclusions: TRBO was significantly longer in the SEMS group. Regardless of whether SEMSs or ISs were placed during the first intervention, patient survival was similar. Using easily removable ISs first might be a reasonable option because TRBO with SEMSs was shorter than patient survival. Cholangitis is a problem associated with the placement of IS.

Indexed as

cholangiocarcinomacholangitisendoscopic retrograde cholangiopancreatographyinside stentmetal stentstent

Identifiers

PMID35601126
PMCPMC9120877
OpenAlexW4223984312

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.