Evidence map›Paper›PMID 35600672›Full record

ArticleIEEE access : practical innovations, open solutions2022

Characterization of a Low-Profile, Flexible, and Acoustically Transparent Receive-Only MRI Coil Array for High Sensitivity MR-Guided Focused Ultrasound.

Isabelle Saniour, Fraser J L Robb, Victor Taracila, Vishwas Mishra, Jana Vincent, Henning U Voss, Michael G Kaplitt, J Levi Chazen, Simone Angela Winkler

Abstract read
In one paragraph

Article in IEEE access : practical innovations, open solutions, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Adaptable, wearable, and stretchable coils: A review.Magnetic resonance in medicine · 2025
    Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Isabelle SaniourDepartment of Radiology, Weill Cornell Medicine, NewYork-Presbyterian Hospital, New York, NY 10065, USA.ORCID 0000-0002-0349-0311
Fraser J L RobbMR Engineering, GE Healthcare Coils, Aurora, OH 44202, USA.
Victor TaracilaMR Engineering, GE Healthcare Coils, Aurora, OH 44202, USA.
Vishwas MishraDepartment of Radiology, Weill Cornell Medicine, NewYork-Presbyterian Hospital, New York, NY 10065, USA.
Jana VincentMR Engineering, GE Healthcare Coils, Aurora, OH 44202, USA.
Henning U VossDepartment of Radiology, Weill Cornell Medicine, NewYork-Presbyterian Hospital, New York, NY 10065, USA.
Michael G KaplittDepartment of Neurological Surgery, Weill Cornell Medicine, NewYork-Presbyterian Hospital, New York, NY 10065, USA.
J Levi ChazenDepartment of Radiology, Weill Cornell Medicine, NewYork-Presbyterian Hospital, New York, NY 10065, USA.
Simone Angela WinklerDepartment of Radiology, Weill Cornell Medicine, NewYork-Presbyterian Hospital, New York, NY 10065, USA.ORCID 0000-0002-8080-9488

Funding

Human Connectome Mapping Using Ultra-High-Resolution MRI: A Technological PathwayR00EB024341 · NIBIB · WEILL MEDICAL COLL OF CORNELL UNIV · PI WINKLER, SIMONE ANGELA · 2019 to 2021
$726k
NIBIB NIH HHS R00 EB024341
6 · The paper itself

Abstract

Magnetic resonance guided focused ultrasound (MRgFUS) is a non-invasive therapeutic modality for neurodegenerative diseases that employs real-time imaging and thermometry monitoring of targeted regions. MRI is used in guidance of ultrasound treatment; however, the MR image quality in current clinical applications is poor when using the vendor built-in body coil. We present an 8-channel, ultra-thin, flexible, and acoustically transparent receive-only head coil design (FUS-Flex) to improve the signal-to-noise ratio (SNR) and thus the quality of MR images during MRgFUS procedures. Acoustic simulations/experiments exhibit transparency of the FUS-Flex coil as high as 97% at 650 kHz. Electromagnetic simulations show a SNR increase of 13× over the body coil. In vivo results show an increase of the SNR over the body coil by a factor of 7.3 with 2× acceleration (equivalent to 11× without acceleration) in the brain of a healthy volunteer, which agrees well with simulation. These preliminary results show that the use of a FUS-Flex coil in MRgFUS surgery can increase MR image quality, which could yield improved focal precision, real-time intraprocedural anatomical imaging, and real-time 3D thermometry mapping.

Indexed as

coilsMagnetic resonance imagingultrasonic transducer arrays

Identifiers

PMID35600672
PMCPMC9119199

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.