Evidence map›Paper›PMID 35599746›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering

Non-circular CBCT orbit design and realization on a clinical robotic C-arm for metal artifact reduction.

Yiqun Ma, Grace J Gang, Tina Ehtiati, Tess Reynolds, Tom Russ, Wenying Wang, Clifford Weiss, Nicholas Theodore, Kelvin Hong, Jeffrey Siewerdsen and 1 more

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Automated Digital Image Optimisation in Intraoperative 2D and 3D Imaging Using a Mobile C-Arm With Flat-Panel Detector.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
  2. Article
  3. Article
  4. Article
  5. Practical workflow for arbitrary non-circular orbits for CT with clinical robotic C-arms.Proceedings of SPIE--the International Society for Optical Engineering · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yiqun MaJohns Hopkins University, Baltimore, MD, USA.
Grace J GangJohns Hopkins University, Baltimore, MD, USA.
Tina EhtiatiSiemens Healthineers.
Tess ReynoldsUniversity of Sydney, Sydney, Australia.
Tom RussHeidelberg University, Mannheim, Germany.
Wenying WangJohns Hopkins University, Baltimore, MD, USA.
Clifford WeissJohns Hopkins University, Baltimore, MD, USA.
Nicholas TheodoreJohns Hopkins University, Baltimore, MD, USA.
Kelvin HongJohns Hopkins University, Baltimore, MD, USA.
Jeffrey SiewerdsenJohns Hopkins University, Baltimore, MD, USA.
J Webster StaymanJohns Hopkins University, Baltimore, MD, USA.

Funding

Task-Driven 3D Interventional ImagingR01EB027127 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER · 2019 to 2022
$1.8M
NIBIB NIH HHS R01 EB027127
6 · The paper itself

Abstract

Metal artifacts have been a difficult challenge for cone-beam CT (CBCT), especially for intraoperative imaging. Metal surgical tools and implants are often present in the field of view and can attenuate X-rays so heavily that they essentially create a missing-data problem. Recently, an increasing number of intra-operative imaging systems such as robotic C-arms are capable of non-circular orbits for data acquisition. Such trajectories can potentially improve sampling and the degree of data completeness to solve the metal-induced missing-data problem, thereby reducing or eliminating the associated image artifacts. In this work, we extend our prior theoretical and experimental work and implement non-circular orbits for metal artifact reduction on a clinical robotic C-arm (Siemens Artis zeego). To maximize the potential for clinical translation, we restrict our implementation to standard built-in motion and data collection functions, also available on other zeego systems, and work within the physical constraints and limitations on positioning and motion. Customized software tools for data extraction, processing, calibration, and reconstruction are used. We demonstrate example non-circular orbits and the resulting image quality using a phantom containing pedicle screws for spine fixation. As compared with a standard circular CBCT orbit, these non-circular orbits exhibit significantly reduced metal artifacts. These results suggest a high potential for image quality improvements for intraoperative CBCT imaging when metal tools or implants are present in the field-of-view.

Indexed as

CBCTimage guidancemetal artifactnon-circular orbitsrobotic C-armsampling

Identifiers

PMID35599746
PMCPMC9119360

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.