Evidence map›Paper›PMID 35596151›Full record

ArticleBMC medical research methodology2022

Detecting accelerometer non-wear periods using change in acceleration combined with rate-of-change in temperature.

Adam Vert, Kyle S Weber, Vanessa Thai, Erin Turner, Kit B Beyer, Benjamin F Cornish, F Elizabeth Godkin, Christopher Wong, William E McIlroy, Karen Van Ooteghem

Open access · goldAbstract read
In one paragraph

Article in BMC medical research methodology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
2.7field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it, 24 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Adam VertDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada.
Kyle S WeberDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada.
Vanessa ThaiDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada.
Erin TurnerDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada.
Kit B BeyerDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada.
Benjamin F CornishDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada.
F Elizabeth GodkinDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada.
Christopher WongDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada.
William E McIlroyDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada.
Karen Van OoteghemDepartment of Kinesiology and Health Sciences, Faculty of Health, University of Waterloo, 200 University Ave, Waterloo, ON, N2L 3G1, Canada. kvanoote@uwaterloo.ca.
University of Waterloo · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccelerometery is commonly used to estimate physical activity, sleep, and sedentary behavior. In free-living conditions, periods of device removal (non-wear) can lead to misclassification of behavior with consequences for research outcomes and clinical decision making. Common methods for non-wear detection are limited by data transformations (e.g., activity counts) or algorithm parameters such as minimum durations or absolute temperature thresholds that risk over- or under-estimating non-wear time. This study aimed to advance non-wear detection methods by integrating a 'rate-of-change' criterion for temperature into a combined temperature-acceleration algorithm.

methodsData were from 39 participants with neurodegenerative disease (36% female; age: 45-83 years) who wore a tri-axial accelerometer (GENEActiv) on their wrist 24-h per day for 7-days as part of a multi-sensor protocol. The reference dataset was derived from visual inspection conducted by two expert analysts. Linear regression was used to establish temperature rate-of-change as a criterion for non-wear detection. A classification and regression tree (CART) decision tree classifier determined optimal parameters separately for non-wear start and end detection. Classifiers were trained using data from 15 participants (38.5%). Outputs from the CART analysis were supplemented based on edge cases and published parameters.

resultsThe dataset included 186 non-wear periods (85.5% < 60 min). Temperature rate-of-change over the first five minutes of non-wear was - 0.40 ± 0.17 °C/minute and 0.36 ± 0.21 °C/minute for the first five minutes following device donning. Performance of the DETACH (DEvice Temperature and Accelerometer CHange) algorithm was improved compared to existing algorithms with recall of 0.942 (95% CI 0.883 to 1.0), precision of 0.942 (95% CI 0.844 to 1.0), F1-Score of 0.942 (95% CI 0.880 to 1.0) and accuracy of 0.996 (0.994-1.000).

conclusionThe DETACH algorithm accurately detected non-wear intervals as short as five minutes; improving non-wear classification relative to current interval-based methods. Using temperature rate-of-change combined with acceleration results in a robust algorithm appropriate for use across different temperature ranges and settings. The ability to detect short non-wear periods is particularly relevant to free-living scenarios where brief but frequent removals occur, and for clinical application where misclassification of behavior may have important implications for healthcare decision-making.

Indexed as

AccelerometryNeurodegenerative DiseasesAccelerationAgedAged, 80 and overFemaleHumansMaleMiddle AgedSedentary BehaviorTemperatureAccelerometryAlgorithmBehavior classificationNon-wear detectionPhysical activityRemote monitoringWearables

Identifiers

PMID35596151
PMCPMC9123693
OpenAlexW4281255248

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.