ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2022
High-power short-duration ablation index-guided pulmonary vein isolation protocol using a single catheter.
Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 20 citations in OpenAlex.
- Single-catheter radiofrequency pulmonary vein isolation for atrial fibrillation: a comparative evaluation.Frontiers in cardiovascular medicine · 2026Article
- Anterior mitral isthmus line using pulsed-field ablation with the pentaspline catheter or radiofrequency ablation: procedural characteristics, safety, and mid-term outcomes.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Article
- Pulsed-field ablation versus radiofrequency ablation in patients undergoing repeat catheter ablation for atrial fibrillation.Heart rhythm O2 · 2025Article
- Contemporary Trends in Pulsed Field Ablation for Cardiac Arrhythmias.Journal of cardiovascular development and disease · 2024Review
- Comparing cryoballoon and contact-force guided radiofrequency ablation in pulmonary vein isolation for atrial fibrillation in patients with hypertrophic cardiomyopathy.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2024Article
- Pulmonary Vein Isolation for Atrial Fibrillation: Comparison of a Very High-Power Very Short-Duration (vHPvSD) Ablation Protocol versus a Hybrid Ablation Approach-Procedural and Mid-Term Outcome Data.Journal of clinical medicine · 2024Article
- Repeat catheter ablation after very late recurrence of atrial fibrillation after pulmonary vein isolation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024Article
- Silent cerebral lesions following catheter ablation for atrial fibrillation: a state-of-the-art review.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023Review
Corrections and comments
- Commented on by
Authors and funding
10 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCatheter ablation for atrial fibrillation (AF) is the most commonly performed electrophysiological procedure. To improve healthcare utilization, we aimed to compare the efficacy, efficiency, and safety of a minimalistic, streamlined single catheter ablation approach using a high-power short-duration ablation index-guided protocol (HPSD) vs. a control single-catheter protocol (SP).
methodsPulmonary vein isolation (PVI) with a single transseptal puncture without a multipolar mapping catheter was performed in 91 patients. Left atrial mapping was performed with the ablation catheter, only. Pacing maneuvers were used to confirm exit block. Procedural characteristics and success rates were compared using HPSD (n = 34) vs. a control (n = 57) ablation protocol. Freedom from recurrence was defined as a 1-year absence of AF episodes > 30 s, beyond the 3-month blanking period.
resultsUsing the HPSD protocol the median procedure and RF ablation time were significantly shorter compared to the SP, 84 (IQR 76-100) vs. 118 min (IQR 104-141) and 1036 (898-1184) vs. 1949s (IQR 1693-2261), respectively, p < .001 for all. First-pass PVI was achieved using the HPSD protocol in 88% and using the SP in 87% of patients, p = 1.0. No procedural complications were observed. High-sensitivity cardiac troponin levels were significantly higher in patients using the HPSD protocol compared to the SP. At 12 months follow-up, 87% patients remained free from AF with no differences between groups.
conclusionsA minimalistic, HPSD ablation index-guided PVI with a single-catheter approach is very efficient, safe, and associated with excellent clinical outcomes at 1 year.