Evidence map›Paper›PMID 35593986›Full record

ArticleInternational journal of computer assisted radiology and surgery2022

Service-oriented Device Connectivity interface for a situation recognition system in the OR.

Denise Junger, Patrick Beyersdorffer, Christian Kücherer, Oliver Burgert

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. A high-fidelity prototype of a sterile information system for the perioperative area: OR-Pad.International journal of computer assisted radiology and surgery · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Denise Junger *School of Informatics, Research Group Computer Assisted Medicine (CaMed), Reutlingen University, Reutlingen, Germany. denise.junger@reutlingen-university.de.ORCID http://orcid.org/0000-0002-7895-3210
Patrick Beyersdorffer *School of Informatics, Research Group Computer Assisted Medicine (CaMed), Reutlingen University, Reutlingen, Germany.ORCID http://orcid.org/0000-0002-4067-5729
Christian KüchererSchool of Informatics, Research Group Computer Assisted Medicine (CaMed), Reutlingen University, Reutlingen, Germany.ORCID http://orcid.org/0000-0001-5608-482X
Oliver BurgertSchool of Informatics, Research Group Computer Assisted Medicine (CaMed), Reutlingen University, Reutlingen, Germany.ORCID http://orcid.org/0000-0001-7118-4730
Reutlingen University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeContext awareness in the operating room (OR) is important to realize targeted assistance to support actors during surgery. A situation recognition system (SRS) is used to interpret intraoperative events and derive an intraoperative situation from these. To achieve a modular system architecture, it is desirable to de-couple the SRS from other system components. This leads to the need of an interface between such an SRS and context-aware systems (CAS). This work aims to provide an open standardized interface to enable loose coupling of the SRS with varying CAS to allow vendor-independent device orchestrations.

methodsA requirements analysis investigated limiting factors that currently prevent the integration of CAS in today's ORs. These elicited requirements enabled the selection of a suitable base architecture. We examined how to specify this architecture with the constraints of an interoperability standard. The resulting middleware was integrated into a prototypic SRS and our system for intraoperative support, the OR-Pad, as exemplary CAS for evaluating whether our solution can enable context-aware assistance during simulated orthopedical interventions.

resultsThe emerging Service-oriented Device Connectivity (SDC) standard series was selected to specify and implement a middleware for providing the interpreted contextual information while the SRS and CAS are loosely coupled. The results were verified within a proof of concept study using the OR-Pad demonstration scenario. The fulfillment of the CAS' requirements to act context-aware, conformity to the SDC standard series, and the effort for integrating the middleware in individual systems were evaluated. The semantically unambiguous encoding of contextual information depends on the further standardization process of the SDC nomenclature. The discussion of the validity of these results proved the applicability and transferability of the middleware.

conclusionThe specified and implemented SDC-based middleware shows the feasibility of loose coupling an SRS with unknown CAS to realize context-aware assistance in the OR.

Indexed as

Operating RoomsSurgery, Computer-AssistedHumansContext awarenessContext-aware systemIntraoperative areaOR-PadSDCSituation recognition system

Identifiers

PMID35593986
PMCPMC9515014
OpenAlexW4280535548

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.