ArticleEuropean heart journal. Case reports2022
Iatrogenic pacemaker-induced ventricular arrhythmia: a case report.
Article in European heart journal. Case reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Minimizing right ventricular (RV) pacing to reduce the progression of heart failure is an established practice. Proprietary algorithms to reduce unnecessary RV pacing have been incorporated into both simple and complex cardiac pacemaker devices, for reducing the possibility of heart failure and arrhythmias. Case summary: We present a case of a 43-year-old male implanted with a dual-chamber primary prevention implantable cardioverter-defibrillator (AUTOGEN EL, Boston Scientific) for sudden cardiac death. At the time of implant, the patient had hypertrophic cardiomyopathy with mild left ventricular (LV) systolic impairment, and sinus rhythm with intact atrioventricular (AV) conduction. The patient developed progression of his disease with symptoms (dyspnoea) and LV impairment. This led to a decision to activate the minimal RV pacing algorithm (RYTHMIQ™). A deterioration in AV conduction caused intrinsic ventricular beats to fall in the atrial blanking period, and subsequent VVI backup pacing resulted in R on T pacing. This induced ventricular arrhythmia. RYTHMIQ™ was subsequently deactivated, and the patient has had no further device-induced arrhythmias. Discussion: Numerous studies have demonstrated the adverse effect of RV pacing on LV function. Minimizing RV pacing is, therefore, encouraged in individuals with intact AV conduction. However, underlying conduction abnormalities must be assessed prior to activating algorithms designed to minimize RV pacing. This case demonstrates the importance of careful intracardiac electrogram interpretation and individual case-based device programming, to avoid device-induced complications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.