Evidence map›Paper›PMID 35591454›Full record

ArticleMaterials (Basel, Switzerland)2022

Biomechanical Efficacy and Effectiveness of Orthodontic Treatment with Transparent Aligners in Mild Crowding Dentition-A Finite Element Analysis.

Jeong-Hee Seo, Min-Seok Kim, Jeong-Hyeon Lee, Emmanuel Eghan-Acquah, Yong-Hoon Jeong, Mi-Hee Hong, Bongju Kim, Sung-Jae Lee

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 20 citations in OpenAlex.

  1. A Novel Double Arrowhead Auxetic Dental Splint for Avulsed Tooth Reimplantation.Dental traumatology : official publication of International Association for Dental Traumatology · 2026
    Article
  2. Article
  3. Article
  4. Observational
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Jeong-Hee SeoR&D Center, DENTIS Co., Ltd., Daegu 41065, Korea.ORCID 0000-0002-6702-1960
Min-Seok KimDepartment of Biomedical Engineering, Inje University, Gimhae 50834, Korea.
Jeong-Hyeon LeeDepartment of Biomedical Engineering, Inje University, Gimhae 50834, Korea.
Emmanuel Eghan-AcquahSchool of Health Sciences and Social Work, Griffith University, Gold Coast, QLD 4222, Australia.ORCID 0000-0002-0011-6981
Yong-Hoon JeongOsong Medical Innovation Foundation, Cheongju 28160, Korea.
Mi-Hee HongDepartment of Orthodontics, School of Dentistry, Kyungpook National University, Daegu 41940, Korea.ORCID 0000-0001-6015-1482
Bongju KimDental Life Science Research Institute, Seoul National University Dental Hospital, Seoul 03080, Korea.ORCID 0000-0001-7309-5977
Sung-Jae LeeDepartment of Biomedical Engineering, Inje University, Gimhae 50834, Korea.
Inje University · KRGriffith University · AUKyungpook National University · KROsong Medical Innovation Foundation · KRSeoul National University Dental Hospital · KR

Funding

Ministry of Trade, Industry and Energy 20006105
6 · The paper itself

Abstract

Orthodontic treatment increasingly involves transparent aligners; however, biomechanical analysis of their treatment effects under clinical conditions is lacking. We compared the biomechanical efficacy and effectiveness of orthodontic treatment with transparent aligners and of fixed appliances in simulated clinical orthodontic treatment conditions using orthodontic finite element (FE) models. In the FE analysis, we used Model Activation/De-Activation analysis to validate our method. Fixed appliances and 0.75-mm and 0.5-mm thick transparent aligners were applied to a tooth-alveolar bone FE model with lingually-inclined and axially-rotated central incisors. Compared to the fixed appliance, the 0.75-mm and 0.5-mm transparent aligners induced 5%, 38%, and 28% and 21%, 62%, and 34% less movement of the central incisors and principal stress of the periodontal ligament and of the alveolar bone, respectively, for lingual inclination correction. For axial-rotation correction, these aligners induced 22%, 37%, and 40% and 28%, 67%, and 48% less tooth movement and principal stress of the periodontal ligament and of the alveolar bone, respectively. In conclusion, transparent aligners induced less tooth movement, it is sufficient for orthodontic treatment, but 0.5-mm aligners should be used for only mild corrections. Additionally, the Model Activation/De-Activation analysis method is suitable for FE analysis of orthodontic treatment reflecting clinical treatment conditions.

Indexed as

biomechanical efficacy and effectivenessfinite element analysismodel activation/de-activation methodorthodontic treatmenttransparent aligner

Identifiers

PMID35591454
PMCPMC9104142
OpenAlexW4225012149

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.