Evidence map›Paper›PMID 35591190›Full record

ArticleSensors (Basel, Switzerland)2022

A Soft Multi-Axis High Force Range Magnetic Tactile Sensor for Force Feedback in Robotic Surgical Systems.

Muhammad Rehan, Muhammad Mubasher Saleem, Mohsin Islam Tiwana, Rana Iqtidar Shakoor, Rebecca Cheung

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Muhammad RehanDepartment of Mechatronics Engineering, National University of Sciences and Technology, Islamabad 44000, Pakistan.ORCID 0000-0001-8497-1397
Muhammad Mubasher SaleemDepartment of Mechatronics Engineering, National University of Sciences and Technology, Islamabad 44000, Pakistan.ORCID 0000-0002-9398-4103
Mohsin Islam TiwanaDepartment of Mechatronics Engineering, National University of Sciences and Technology, Islamabad 44000, Pakistan.
Rana Iqtidar ShakoorNational Centre of Robotics and Automation (NCRA), Islamabad 44000, Pakistan.
Rebecca CheungInstitute for Integrated Micro and Nano Systems, School of Engineering, University of Edinburgh, Scottish Microelectronics Centre, Edinburgh EH9 3FF, UK.ORCID 0000-0002-2656-5646

Funding

Higher Education Commission Innovative and Collaborative Research Partnerships Grants (ICRG) program Project No. 147
6 · The paper itself

Abstract

This paper presents a multi-axis low-cost soft magnetic tactile sensor with a high force range for force feedback in robotic surgical systems. The proposed sensor is designed to fully decouple the output response for normal, shear and angular forces. The proposed sensor is fabricated using rapid prototyping techniques and utilizes Neodymium magnets embedded in an elastomer over Hall sensors such that their displacement produces a voltage change that can be used to calculate the applied force. The initial spacing between the magnets and the Hall sensors is optimized to achieve a large displacement range using finite element method (FEM) simulations. The experimental characterization of the proposed sensor is performed for applied force in normal, shear and 45° angular direction. The force sensitivity of the proposed sensor in normal, shear and angular directions is 16 mV/N, 30 mV/N and 81 mV/N, respectively, with minimum mechanical crosstalk. The force range for the normal, shear and angular direction is obtained as 0-20 N, 0-3.5 N and 0-1.5 N, respectively. The proposed sensor shows a perfectly linear behavior and a low hysteresis error of 8.3%, making it suitable for tactile sensing and biomedical applications. The effect of the material properties of the elastomer on force ranges and sensitivity values of the proposed sensor is also discussed.

Indexed as

Robotic Surgical ProceduresElastomersFeedbackMagnetic PhenomenaMechanical PhenomenaElastomerselastomerforce rangeHall sensormagnetic tactile sensormulti-axisrobotic surgery

Identifiers

PMID35591190
PMCPMC9105633

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.