ArticleSensors (Basel, Switzerland)2022
Correction Model for Metal Oxide Sensor Drift Caused by Ambient Temperature and Humidity.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Performance Assessment of the Earthview BluBird Continuous Emission Monitoring System for Oil and Gas Facility Emissions Monitoring.Sensors (Basel, Switzerland) · 2026Article
- Multimodal, wearable sensors with tactile communication capabilities for human and robotic applications.Device · 2026Article
- Adaptive E-Nose: Integrating New Gas Sensors for Emerging Applications.Sensors (Basel, Switzerland) · 2026Article
- BreathSense: A Two-Stage Digital Framework for Student Stress Monitoring Using Personalized Breath-VOC Thresholding and In-the-Wild Validation.Behavioral sciences (Basel, Switzerland) · 2026Article
- Precision Gas Sensing Interface Circuit with Digital Potentiometer-Based Dynamic Gain Control.Sensors (Basel, Switzerland) · 2026Article
- High-Resolution Wind Tunnel Dataset of Gas Sensor Responses to Vapor Plumes in Scale Model Landscapes.Scientific data · 2026Article
- Presence-gated VOC sensing for urban search and rescue applications.Scientific reports · 2026Article
- Radon Exposure Assessment: IoT-Embedded Sensors.Sensors (Basel, Switzerland) · 2025Review
- Development of an E-Nose System for the Early Diagnosis of Sepsis During Mechanical Ventilation: A Porcine Feasibility Study.Sensors (Basel, Switzerland) · 2025Article
- Real-Time Monitoring of Odour Emissions at the Fenceline of a Waste Treatment Plant by Instrumental Odour Monitoring Systems: Focus on Training Methods.Sensors (Basel, Switzerland) · 2024Article
- Application of Machine Learning for Calibrating Gas Sensors for Methane Emissions Monitoring.Sensors (Basel, Switzerland) · 2023Article
- Implementation of an electronic nose for real -time identification of odour emission peaks at a wastewater treatment plant.Heliyon · 2023Article
- Reproducibility and Repeatability Tests on (SnTiNb)OSensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
For decades, Metal oxide (MOX) gas sensors have been commercially available and used in various applications such as the Smart City, gas monitoring, and safety due to advantages such as high sensitivity, a high detection range, fast reaction time, and cost-effectiveness. However, several factors affect the sensing ability of MOX gas sensors. This article presents the results of a study on the cross-sensitivity of MOX gas sensors toward ambient temperature and humidity. A gas sensor array consisting of temperature and humidity sensors and four different MOX gas sensors (MiCS-5524, GM-402B, GM-502B, and MiCS-6814) was developed. The sensors were subjected to various relative gas concentrations, temperatures (from 16 °C to 30 °C), and humidity levels (from 75% to 45%), representing a typical indoor environment. The results proved that the gas sensor responses were significantly affected by the temperature and humidity. The increased temperature and humidity levels led to a decreased response for all sensors, except for MiCS-6814, which showed the opposite response. Hence, this work proposed regression models for each sensor, which can correct the gas sensor response drift caused by the ambient temperature and humidity variations. The models were validated, and the standard deviations of the corrected sensor response were found to be 1.66 kΩ, 13.17 kΩ, 29.67 kΩ, and 0.12 kΩ, respectively. These values are much smaller compared to the raw sensor response (i.e., 18.22, 24.33 kΩ, 95.18 kΩ, and 2.99 kΩ), indicating that the model provided a more stable output and minimised the drift. Overall, the results also proved that the models can be used for MOX gas sensors employed in the training process, as well as for other sets of gas sensors.