Evidence map›Paper›PMID 35590895›Full record

ArticleSensors (Basel, Switzerland)2022

Contact Compliance Based Visual Feedback for Tool Alignment in Robot Assisted Bone Drilling.

Ping-Lang Yen, Yu-Jui Chen

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ping-Lang YenDepartment of Biomechatronics Engineering, National Taiwan University, Taipei 10617, Taiwan.ORCID 0000-0001-8020-6241
Yu-Jui ChenDepartment of Biomechatronics Engineering, National Taiwan University, Taipei 10617, Taiwan.

Funding

Ministry of Science and Technology, Taiwan 109-2218-E-002-035, 110-2218-E-002-041
6 · The paper itself

Abstract

In recent decades, robot-assisted surgery has been proven superior at providing more accurate outcomes than the conventional one, particularly in minimally invasive procedures. However, there are still limitations to these kinds of surgical robots. Accurate bone drilling on the steep and hard surface of cortical bone is still challenging. The issues of slipping away from the target entry point on the bone surface and subsequently deviating from the desired path are still not completely solved. Therefore, in this paper, a force control is proposed to accompany the resolved motion rate controller in a handheld orthopedic robot system. The force control makes it possible to adjust the contact compliance of the drill to the bone surface. With the proper contact compliance, the drill can be prevented from deflecting in contact with the bone surface, and will eventually be directed to the target entry point. The experiments on test jig and vertebra phantom also show that the robot under the proposed contact compliance visual feedback control structure could produce better usability positioning accuracy under various contact disturbances than its counterpart.

Indexed as

OrthopedicsRoboticsRobotic Surgical ProceduresSurgery, Computer-AssistedFeedback, Sensoryforce controlhuman robot collaborationmedical robotsurgical robot

Identifiers

PMID35590895
PMCPMC9103330

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.