Evidence map›Paper›PMID 35590859›Full record

ArticleSensors (Basel, Switzerland)2022

Motion Artifacts Correction from Single-Channel EEG and fNIRS Signals Using Novel Wavelet Packet Decomposition in Combination with Canonical Correlation Analysis.

Md Shafayet Hossain, Muhammad E H Chowdhury, Mamun Bin Ibne Reaz, Sawal Hamid Md Ali, Ahmad Ashrif A Bakar, Serkan Kiranyaz, Amith Khandakar, Mohammed Alhatou, Rumana Habib, Muhammad Maqsud Hossain

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. EEG Signal Processing for Biomedical Applications.Sensors (Basel, Switzerland) · 2022
    Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Md Shafayet HossainDepartment of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia.
Muhammad E H ChowdhuryDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0003-0744-8206
Mamun Bin Ibne ReazDepartment of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia.ORCID 0000-0002-0459-0365
Sawal Hamid Md AliDepartment of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia.ORCID 0000-0002-4819-863X
Ahmad Ashrif A BakarDepartment of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia.ORCID 0000-0002-9060-0346
Serkan KiranyazDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.
Amith KhandakarDepartment of Electrical Engineering, Qatar University, Doha 2713, Qatar.ORCID 0000-0001-7068-9112
Mohammed AlhatouNeuromuscular Division, Department of Neurology, Al-Khor Branch, Hamad General Hospital, Doha 3050, Qatar.ORCID 0000-0001-9795-6137
Rumana HabibDepartment of Neurology, BIRDEM General Hospital, Dhaka 1000, Bangladesh.
Muhammad Maqsud HossainNSU Genome Research Institute (NGRI), North South University, Dhaka 1229, Bangladesh.ORCID 0000-0001-9794-411X

Funding

International Research Collaboration Co-Fund (IRCC) IRCC-2021-001Qatar National Research Fund (QNRF) NPRP12S-0227-190164Universiti Kebangsaan Malaysia DPK-2021-001
6 · The paper itself

Abstract

The electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) signals, highly non-stationary in nature, greatly suffers from motion artifacts while recorded using wearable sensors. Since successful detection of various neurological and neuromuscular disorders is greatly dependent upon clean EEG and fNIRS signals, it is a matter of utmost importance to remove/reduce motion artifacts from EEG and fNIRS signals using reliable and robust methods. In this regard, this paper proposes two robust methods: (i) Wavelet packet decomposition (WPD) and (ii) WPD in combination with canonical correlation analysis (WPD-CCA), for motion artifact correction from single-channel EEG and fNIRS signals. The efficacy of these proposed techniques is tested using a benchmark dataset and the performance of the proposed methods is measured using two well-established performance matrices: (i) difference in the signal to noise ratio ( ) and (ii) percentage reduction in motion artifacts ( ). The proposed WPD-based single-stage motion artifacts correction technique produces the highest average (29.44 dB) when db2 wavelet packet is incorporated whereas the greatest average (53.48%) is obtained using db1 wavelet packet for all the available 23 EEG recordings. Our proposed two-stage motion artifacts correction technique, i.e., the WPD-CCA method utilizing db1 wavelet packet has shown the best denoising performance producing an average and values of 30.76 dB and 59.51%, respectively, for all the EEG recordings. On the other hand, for the available 16 fNIRS recordings, the two-stage motion artifacts removal technique, i.e., WPD-CCA has produced the best average (16.55 dB, utilizing db1 wavelet packet) and largest average (41.40%, using fk8 wavelet packet). The highest average and using single-stage artifacts removal techniques (WPD) are found as 16.11 dB and 26.40%, respectively, for all the fNIRS signals using fk4 wavelet packet. In both EEG and fNIRS modalities, the percentage reduction in motion artifacts increases by 11.28% and 56.82%, respectively when two-stage WPD-CCA techniques are employed in comparison with the single-stage WPD method. In addition, the average also increases when WPD-CCA techniques are used instead of single-stage WPD for both EEG and fNIRS signals. The increment in both and values is a clear indication that two-stage WPD-CCA performs relatively better compared to single-stage WPD. The results reported using the proposed methods outperform most of the existing state-of-the-art techniques.

Indexed as

ArtifactsCanonical Correlation AnalysisAlgorithmsElectroencephalographyMotionSignal Processing, Computer-AssistedWavelet Analysiscanonical correlation analysis (CCA)electroencephalogram (EEG)functional near-infrared spectroscopy (fNIRS)motion artifactwavelet packet decomposition (WPD)

Identifiers

PMID35590859
PMCPMC9102309

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.