ArticleMedical physics2022
Four-dimensional computed tomography of the left ventricle, Part I: Motion artifact reduction.
Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 10 citations in OpenAlex.
- An end-to-end neural network for 4D cardiac CT reconstruction using single-beat scans.Physics in medicine and biology · 2025Article
- 3D regional evaluation of right ventricular myocardial work from cineCT.medRxiv : the preprint server for health sciences · 2024Article
- Protocol optimization for functional cardiac CT imaging using noise emulation in the raw data domain.Medical physics · 2024Article
- Protocol Optimization for Functional Cardiac CT Imaging Using Noise Emulation in the Raw Data Domain.ArXiv · 2024Article
- Cardiac CT in CRT as a Singular Imaging Modality for Diagnosis and Patient-Tailored Management.Journal of clinical medicine · 2023Review
- DiFiR-CT: Distance field representation to resolve motion artifacts in computed tomography.Medical physics · 2023Article
- Regional left ventricular endocardial strains estimated from low-dose 4DCT: Comparison with cardiac magnetic resonance feature tracking.Medical physics · 2022Article
- Prediction of Cardiac Resynchronization Therapy Response Using a Lead Placement Score Derived From 4-Dimensional Computed Tomography.Circulation. Cardiovascular imaging · 2022Article
- Four-dimensional computed tomography of the left ventricle, Part II: Estimation of mechanical activation times.Medical physics · 2022Article
- Motion correction of wide-detector 4DCT images for cardiac resynchronization therapy planning.Journal of cardiovascular computed tomographyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
Abstract
purposeStandard four-dimensional computed tomography (4DCT) cardiac reconstructions typically include spiraling artifacts that depend not only on the motion of the heart but also on the gantry angle range over which the data was acquired. We seek to reduce these motion artifacts and, thereby, improve the accuracy of left ventricular wall positions in 4DCT image series.
methodsWe use a motion artifact reduction approach (ResyncCT) that is based largely on conjugate pairs of partial angle reconstruction (PAR) images. After identifying the key locations where motion artifacts exist in the uncorrected images, paired subvolumes within the PAR images are analyzed with a modified cross-correlation function in order to estimate 3D velocity and acceleration vectors at these locations. A subsequent motion compensation process (also based on PAR images) includes the creation of a dense motion field, followed by a backproject-and-warp style compensation. The algorithm was tested on a 3D printed phantom, which represents the left ventricle (LV) and on challenging clinical cases corrupted by severe artifacts.
resultsThe results from our preliminary phantom test as well as from clinical cardiac scans show crisp endocardial edges and resolved double-wall artifacts. When viewed as a temporal series, the corrected images exhibit a much smoother motion of the LV endocardial boundary as compared to the uncorrected images. In addition, quantitative results from our phantom studies show that ResyncCT processing reduces endocardial surface distance errors from 0.9 ± 0.8 to 0.2 ± 0.1 mm.
conclusionsThe ResyncCT algorithm was shown to be effective in reducing motion artifacts and restoring accurate wall positions. Some perspectives on the use of conjugate-PAR images and on techniques for CT motion artifact reduction more generally are also given.