ArticlePrehospital and disaster medicine2022
Medication-Facilitated Advanced Airway Management with First-Line Use of a Supraglottic Device - A One-Year Quality Assurance Review.
Article in Prehospital and disaster medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Safety considerations and risk mitigation strategies for ketamine use: a comprehensive review.Annals of medicine and surgery (2012) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionAirway management is a controversial topic in modern Emergency Medical Services (EMS) systems. Among many concerns regarding endotracheal intubation (ETI), unrecognized esophageal intubation and observations of unfavorable neurologic outcomes in some studies raise the question of whether alternative airway techniques should be first-line in EMS airway management protocols. Supraglottic airway devices (SADs) are simpler to use, provide reliable oxygenation and ventilation, and may thus be an alternative first-line airway device for paramedics. In 2019, Alachua County Fire Rescue (ACFR; Alachua, Florida USA) introduced a novel protocol for advanced airway management emphasizing first-line use of a second-generation SAD (i-gel) for patients requiring medication-facilitated airway management (referred to as "rapid sequence airway" [RSA] protocol). STUDY
objectiveThis was a one-year quality assurance review of care provided under the RSA protocol looking at compliance and first-pass success rate of first-line SAD use.
methodsRecords were obtained from the agency's electronic medical record (EMR), searching for the use of the RSA protocol, advanced airway devices, or either ketamine or rocuronium. If available, hospital follow-up data regarding patient condition and emergency department (ED) airway exchange were obtained.
resultsDuring the first year, 33 advanced airway attempts were made under the protocol by 23 paramedics. Overall, compliance with the airway device sequence as specified in the protocol was 72.7%. When ETI was non-compliantly used as first-line airway device, the first-pass success rate was 44.4% compared to 87.5% with adherence to first-line SAD use. All prehospital SADs were exchanged in the ED in a delayed fashion and almost exclusively per physician preference alone. In no case was the SAD exchanged for suspected dislodgement evidenced by lack of capnography.
conclusionFirst-line use of a SAD was associated with a high first-pass attempt success rate in a real-life cohort of prehospital advanced airway encounters. No SAD required emergent exchange upon hospital arrival.