Design and optimization of thin-film tungsten (W)-diamond target for multi-pixel X-ray sources.

Yuewen Tan, Qinghao Chen, Shuang Zhou, Erik A Henriksen, Tiezhi Zhang

Abstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Deconvoluting thermomechanical effects in X-ray diffraction data using machine learning.Acta crystallographica. Section A, Foundations and advances · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yuewen TanDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, Missouri, USA.ORCID https://orcid.org/0000-0001-5932-0824
Qinghao ChenDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, Missouri, USA.ORCID https://orcid.org/0000-0003-2939-5918
Shuang ZhouDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, Missouri, USA.
Erik A HenriksenDepartment of Physics, Washington University in St. Louis, St. Louis, Missouri, USA.ORCID https://orcid.org/0000-0002-4978-2440
Tiezhi ZhangDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, Missouri, USA.

Funding

Super-resolution dual-energy dental CT based on distributed x-ray source and photon counting detectorR41DE029727 · NIDCR · TETRAIMAGING, LLC · PI TOKER, EMRE, ZHANG, TIEZHI · 2021 to 2021
$222k
DEVELOPMENT OF A NOVEL W-PG LAMINATE X-RAY TARGET WITH IMPROVED FOCAL SPOT POWER DENSITYR03EB024952 · NIBIB · WASHINGTON UNIVERSITY · PI ZHANG, TIEZHI · 2017 to 2018
$153k
NIBIB NIH HHS R03 EB024952NIDCR NIH HHS R41 DE029727
6 · The paper itself

Abstract

backgroundEmerging multi-pixel X-ray source technology enables new designs for X-ray imaging systems. The power of multi-pixel X-ray sources with a fixed anode is limited by focal spot power density. PURPOSE: The purpose of this study is to optimize the W-diamond target and predict its performance in multi-pixel X-ray sources.

methodsX-ray intensity and energy deposition in the W-diamond target with different thicknesses of tungsten film and incident electron energies was calculated with the Geant4 Monte Carlo toolkit. COMSOL Multiphysics software was used to analyze the transient and stationary heat transfer in the thin-film W-diamond target. The maximum tube power and X-ray output intensity were predicted for both transmission and reflection target configurations.

resultsThe maximum focal spot power density was limited by either the graphitization of the diamond substrate or the melting point of the W target. With optimal W-target thickness, the maximum transmission X-ray intensities are about 40%-50% higher than the maximum reflection intensities. Thin-film W-diamond targets allow four to five times more maximum power input and produce six to seven times higher transmission X-ray intensity in continuous mode compared with conventional reflection W thick targets. Depending on the focal spot size, reducing the X-ray pulse duration can further enhance the tube power.

conclusionsMulti-pixel X-ray sources using this W-diamond target design can produce significantly higher X-ray output than traditional thick tungsten targets without major modification of the tube design.

Indexed as

multi-pixel X-ray sourcethin-film X-ray targetW-diamond target