Evidence map›Paper›PMID 35586957›Full record

ArticlePhysiological reports2022

Gravity and lymphodynamics.

Thomas Holm-Weber, Rasmus Eskild Kristensen, Sheyanth Mohanakumar, Vibeke E Hjortdal

Open access · goldAbstract read
In one paragraph

Article in Physiological reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Octreotide improves human lymphatic fluid transport a translational trial.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2024
    Trial
  2. Article
  3. Review
  4. Article
  5. Gravity and lymphodynamics.Physiological reports · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Thomas Holm-WeberDepartment of Cardiothoracic Surgery, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.ORCID 0000-0001-8683-3254
Rasmus Eskild KristensenDepartment of Cardiothoracic Surgery, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.
Sheyanth MohanakumarDepartment of Cardiothoracic Surgery, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.ORCID 0000-0002-4368-2246
Vibeke E HjortdalDepartment of Cardiothoracic Surgery, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.
University of Copenhagen · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The lymphatic system is compromised in different groups of patients. To recognize pathology, we must know what is healthy. We use Near-Infrared Fluorescence (NIRF) to assess peripheral lymphatic function in humans. We have shown that external factors such as exercise, hyperthermia, and pharmacological mediators influence the function of peripheral lymphatic vessels. In this study, we explored the impact on lymphatic vessels by the ever-present external factor-gravity. We used NIRF imaging to investigate the lymphatic changes to gravity. Gravity was assessed by changing body position from supine to standing. We extracted following lymphatic functional parameters: lymphatic packet propulsion frequency (contractions/min), velocity (cm/s), and pressure (mmHg). Raw data analysis was performed using a custom-written Labview program. All sequences were analyzed by two observers and interclass correlation scores were calculated. All statistical analysis was performed using RStudio Team (2021). RStudio: Integrated Development Environment for R. RStudio, PBC. Healthy participants (n = 17, 11 males, age 28.1 ± 2.6 years) were included. The lymphatic packet propulsion frequency at baseline was 0.5 ± 0.2 contractions/min and rose within 3 min significantly to a maximum of 1.2 ± 0.5 contractions/min during upright posture and remained significantly higher than the baseline lymphatic packet propulsion frequency after lying down again for up to 6 min. The lymph velocity was 1.5 ± 0.4 cm/s at baseline and changed in both directions and without a specific pattern at different points in time during standing. Lymph pressure was significantly higher while standing (mean increase 9 mmHg, CI: 2-15 mmHg). The ICC scores were 89.8% (85.9%-92.7%), 59.3% (46.6%-69.6%) and 89.4% (79.0%-94.8%) in lymphatic packet propulsion frequency (130 observations), velocity (125 observations), and pressure (30 observations), respectively. The lymphatic system responds within few minutes to gravitational changes by increasing lymphatic packet propulsion frequency and pressure.

Indexed as

Lymphatic VesselsAdultGravitationHumansLymphMaleOptical ImagingPosturefluid balancegravitylymphaticsnear-infrared fluorescence imagingphysiology

Identifiers

PMID35586957
PMCPMC9117968
OpenAlexW4280569996

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.