Preliminary study of reliability of transcutaneous sensors in measuring intraabdominal pressure.

Maša Kušar, Mihajlo Djokić, Srdjan Djordjević, Marija Hribernik, Simon Krašna, Blaž Trotovšek

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Maša KušarDepartment of Abdominal Surgery, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Mihajlo DjokićDepartment of Abdominal Surgery, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Srdjan DjordjevićTMG-BMC Ltd., Ljubljana, Slovenia.
Marija HribernikFaculty of Medicine, University of Ljubljana, Ljubljana, Slovenia.
Simon KrašnaFaculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia.
Blaž TrotovšekDepartment of Abdominal Surgery, University Medical Centre Ljubljana, Ljubljana, Slovenia. blaz.trotovsek@kclj.si.
University of Ljubljana · SILjubljana University Medical Centre · SITMG-BMC (Slovenia) · SI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Early recognition of elevated intraabdominal pressure (IAP) in critically ill patients is essential, since it can result in abdominal compartment syndrome, which is a life-threatening condition. The measurement of intravesical pressure is currently considered the gold standard for IAP assessment. Alternative methods have been proposed, where IAP assessment is based on measuring abdominal wall tension, which reflects the pressure in the abdominal cavity. The aim of this study was to evaluate the feasibility of using patch-like transcutaneous sensors to estimate changes in IAP, which could facilitate the monitoring of IAP in clinical practice. This study was performed with 30 patients during early postoperative care. All patients still had an indwelling urinary catheter postoperatively. Four wearable sensors were attached to the outer surface of the abdominal region to detect the changes in abdominal wall tension. Additionally, surface EMG was used to monitor the activity of the abdominal muscles. The thickness of the subcutaneous tissue was measured with ultrasound. Patients performed 4 cycles of the Valsalva manoeuvre, with a resting period in between (the minimal resting period was 30 s, with a prolongation as necessary to ensure that the fluid level in the measuring system had equilibrated). The IAP was estimated with intravesical pressure measurements during all resting periods and all Valsalva manoeuvres, while the sensors continuously measured changes in abdominal wall tension. The association between the subcutaneous thickness and tension changes on the surface and the intraabdominal pressure was statistically significant, but a large part of the variability was explained by individual patient factors. As a consequence, the predictions of IAP using transcutaneous sensors were not biased, but they were quite variable. The specificity of detecting intraabdominal pressure of 20 mmHg and above is 88%, with an NPV of 96%, while its sensitivity and PPV are currently far lower. There are inherent limitations of the chosen preliminary study design that directly caused the low sensitivity of our method as well as the poor agreement with the gold standard method; in spite of that, we have shown that these sensors have the potential to be used to monitor intraabdominal pressure. We are planning a study that would more closely resemble the intended clinical use and expect it to show more consistent results with a far smaller error.

Indexed as

Abdominal CavityAbdominal WallIntra-Abdominal HypertensionAbdomenAbdominal MusclesHumansReproducibility of Results

Identifiers

PMID35585106
PMCPMC9117299
OpenAlexW4280522335

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.