Evidence map›Paper›PMID 35582656›Full record

ArticleIEEE transactions on instrumentation and measurement2022

Deep Generative Learning-Based 1-SVM Detectors for Unsupervised COVID-19 Infection Detection Using Blood Tests.

Abdelkader Dairi, Fouzi Harrou, Ying Sun

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on instrumentation and measurement, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 38 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Abdelkader DairiUniversité des Sciences et de la Technologie d'Oran Mohamed-Boudiaf (USTOMB) Oran 31000 Algérie.ORCID https://orcid.org/0000-0003-4712-6949
Fouzi HarrouComputer, Electrical and Mathematical Sciences and Engineering (CEMSE) DivisionKing Abdullah University of Science and Technology (KAUST) Thuwal 23955-6900 Saudi Arabia.ORCID https://orcid.org/0000-0002-2138-319X
Ying SunComputer, Electrical and Mathematical Sciences and Engineering (CEMSE) DivisionKing Abdullah University of Science and Technology (KAUST) Thuwal 23955-6900 Saudi Arabia.ORCID https://orcid.org/0000-0001-6703-4270
King Abdullah University of Science and Technology · SAUniversité des Sciences et de la Technologie d'Oran Mohamed Boudiaf · DZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A sample blood test has recently become an important tool to help identify false-positive/false-negative real-time reverse transcription polymerase chain reaction (rRT-PCR) tests. Importantly, this is mainly because it is an inexpensive and handy option to detect the potential COVID-19 patients. However, this test should be conducted by certified laboratories, expensive equipment, and trained personnel, and 3-4 h are needed to deliver results. Furthermore, it has relatively large false-negative rates around 15%-20%. Consequently, an alternative and more accessible solution, quicker and less costly, is needed. This article introduces flexible and unsupervised data-driven approaches to detect the COVID-19 infection based on blood test samples. In other words, we address the problem of COVID-19 infection detection using a blood test as an anomaly detection problem through an unsupervised deep hybrid model. Essentially, we amalgamate the features extraction capability of the variational autoencoder (VAE) and the detection sensitivity of the one-class support vector machine (1SVM) algorithm. Two sets of routine blood tests samples from the Albert Einstein Hospital, S ao Paulo, Brazil, and the San Raffaele Hospital, Milan, Italy, are used to assess the performance of the investigated deep learning models. Here, missing values have been imputed based on a random forest regressor. Compared to generative adversarial networks (GANs), deep belief network (DBN), and restricted Boltzmann machine (RBM)-based 1SVM, the traditional VAE, GAN, DBN, and RBM with softmax layer as discriminator layer, and the standalone 1SVM, the proposed VAE-based 1SVM detector offers superior discrimination performance of potential COVID-19 infections. Results also revealed that the deep learning-driven 1SVM detection approaches provide promising detection performance compared to the conventional deep learning models.

Indexed as

COVID-19deep learninggenerative modelsroutine blood testsunsupervised anomaly detection

Identifiers

PMID35582656
PMCPMC8962827
OpenAlexW3216946754

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.