Evidence map›Paper›PMID 35582395›Full record

ArticleJournal of pharmaceutical analysis2022

Rapid and sensitive analysis of trace β-blockers by magnetic solid-phase extraction coupled with Fourier transform ion cyclotron resonance mass spectrometry.

Xue Xiao, Kaili He, Ya-Jun Hou, Zhangmin Xiang, Yunyun Yang

Open access · goldAbstract read
In one paragraph

Article in Journal of pharmaceutical analysis, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Xue XiaoGuangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Guangdong Provincial Engineering Research Center for Ambient Mass Spectrometry, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), Guangzhou, 510070, China.
Kaili HeGuangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Guangdong Provincial Engineering Research Center for Ambient Mass Spectrometry, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), Guangzhou, 510070, China.
Ya-Jun HouGuangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Guangdong Provincial Engineering Research Center for Ambient Mass Spectrometry, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), Guangzhou, 510070, China.
Zhangmin XiangGuangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Guangdong Provincial Engineering Research Center for Ambient Mass Spectrometry, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), Guangzhou, 510070, China.
Yunyun YangGuangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Guangdong Provincial Engineering Research Center for Ambient Mass Spectrometry, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), Guangzhou, 510070, China.
Guangdong Academy of Sciences · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A rapid and sensitive method for analyzing trace β-blockers in complex biological samples, which involved magnetic solid-phase extraction (MSPE) coupled with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), was developed. Novel nanosilver-functionalized magnetic nanoparticles with an interlayer of poly(3,4-dihydroxyphenylalanine) (polyDOPA@Ag-MNPs) were synthesized and used as MSPE adsorbents to extract trace β-blockers from biological samples. After extraction, the analytes loaded on the polyDOPA@Ag-MNPs were desorbed using an organic solvent and analyzed by FTICR-MS. The method was rapid and sensitive, with a total detection procedure of less than 10 min as well as limits of detection and quantification in the ranges of 3.5-6.8 pg/mL and 11.7-22.8 pg/mL, respectively. The accuracy of the method was also desirable, with recoveries ranging from 80.9% to 91.0% following the detection of analytes in human blood samples. All the experimental results demonstrated that the developed MSPE-FTICR-MS method was suitable for the rapid and sensitive analysis of trace β-blockers in complex biological samples.

Indexed as

Fourier transform ion cyclotron resonance mass spectrometryMagnetic solid-phase extractionNanosilver-functionalized magnetic nanoparticlesPoly(3,4-dihydroxyphenylalanine)β-blockers

Identifiers

PMID35582395
PMCPMC9091926
OpenAlexW4200233728

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.