Evidence map›Paper›PMID 35582121›Full record

ArticleIEEE sensors journal2021

Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein.

M Divagar, R Gayathri, Rahiel Rasool, J Kuzhandai Shamlee, Himanshu Bhatia, Jitendra Satija, V V R Sai

Abstract read
In one paragraph

Article in IEEE sensors journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

M DivagarBiomedical Engineering GroupDepartment of Applied MechanicsIndian Institute of Technology Madras Chennai 600036 India.ORCID https://orcid.org/0000-0001-5238-8041
R GayathriBiomedical Engineering GroupDepartment of Applied MechanicsIndian Institute of Technology Madras Chennai 600036 India.
Rahiel RasoolBiomedical Engineering GroupDepartment of Applied MechanicsIndian Institute of Technology Madras Chennai 600036 India.
J Kuzhandai ShamleeBiomedical Engineering GroupDepartment of Applied MechanicsIndian Institute of Technology Madras Chennai 600036 India.
Himanshu BhatiaRicovr Healthcare Inc. Princeton NJ 08542 USA.
Jitendra SatijaCentre for NanobiotechnologyVellore Institute of Technology Vellore 632014 India.ORCID https://orcid.org/0000-0003-1971-4778
V V R SaiBiomedical Engineering GroupDepartment of Applied MechanicsIndian Institute of Technology Madras Chennai 600036 India.ORCID https://orcid.org/0000-0001-5574-8735

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

SARS-CoV-2 nucleocapsid protein-based COVID-19 diagnosis is a promising alternative to the high-priced, time-consuming, and labor-intensive RT-PCR tests. Here, we developed a rapid, dip-type, wash-free plasmonic fiber optic absorbance biosensor (P-FAB) strategy for the point-of-care detection of SARS-CoV-2 N-protein, expressed abundantly during the infection. P-FAB involves a sandwich assay with plasmonic labels on the surface of a U-bent fiber optic sensor probe with a high evanescent wave absorbance (EWA) sensitivity. The SARS-CoV-2 N-protein is quantified in terms of the change in the intensity of the light propagating through the U-bent sensor probe coupled to a green LED and a photodetector. Firstly, the optical fiber material (silica vs. polymeric optical fiber), was evaluated to realize a sensitive sensor platform. The optimal size of AuNP labels (20, 40, and 60 nm) to achieve high sensitivity and a lower limit of detection (LoD) was investigated. Following the P-FAB strategy, fused silica/glass optical fiber (GOF) U-bent senor probe and citrate-capped AuNP labels (size ~40 nm) gave rise to an LoD down to ~2.5 ng/mL within 10 mins of read-out time. Further, studies on development and validation of a point of care (PoC) read-out device, and preclinical studies are in progress.

Indexed as

BiosensorsCOVID-19medical diagnosisnanoparticlesnanophotonicsN-proteinoptical fiber sensorplasmonic fiberoptic absorbance biosensorSARS-CoV-2

Identifiers

PMID35582121
PMCPMC8843044

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked