Malalignment of the total ankle replacement increases peak contact stresses on the bone-implant interface: a finite element analysis.

Sanne W G van Hoogstraten, Joris Hermus, Arjan C Y Loenen, Jacobus J Arts, Bert van Rietbergen

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. [Short-term effectiveness of INBONEZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sanne W G van HoogstratenDepartment of Orthopedic Surgery, Laboratory for Experimental Orthopedics, Maastricht University Medical Center, Maastricht, the Netherlands. s.vanhoogstraten@maastrichtuniversity.nl.
Joris HermusDepartment of Orthopedic Surgery, Laboratory for Experimental Orthopedics, Maastricht University Medical Center, Maastricht, the Netherlands.
Arjan C Y LoenenDepartment of Orthopedic Surgery, Laboratory for Experimental Orthopedics, Maastricht University Medical Center, Maastricht, the Netherlands.
Jacobus J ArtsDepartment of Orthopedic Surgery, Laboratory for Experimental Orthopedics, Maastricht University Medical Center, Maastricht, the Netherlands.
Bert van RietbergenDepartment of Orthopedic Surgery, Laboratory for Experimental Orthopedics, Maastricht University Medical Center, Maastricht, the Netherlands.

Funding

Health~Holland NSP20-1-302
6 · The paper itself

Abstract

introductionMalalignment of the Total Ankle Replacement (TAR) has often been postulated as the main reason for the high incidence of TAR failure. As the ankle joint has a small contact area, stresses are typically high, and malalignment may lead to non-homogeneous stress distributions, including stress peaks that may initiate failure. This study aims to elucidate the effect of TAR malalignment on the contact stresses on the bone-implant interface, thereby gaining more understanding of the potential role of malalignment in TAR failure.

methodsFinite Element (FE) models of the neutrally aligned as well as malaligned CCI (Ceramic Coated Implant) Evolution TAR implant (Van Straten Medical) were developed. The CCI components were virtually inserted in a generic three-dimensional (3D) reconstruction of the tibia and talus. The tibial and talar TAR components were placed in neutral alignment and in 5° and 10° varus, valgus, anterior and posterior malalignment. Loading conditions of the terminal stance phase of the gait cycle were applied. Peak contact pressure and shear stress at the bone-implant interface were simulated and stress distributions on the bone-implant interface were visualized.

resultsIn the neutral position, a peak contact pressure and shear stress of respectively 98.4 MPa and 31.9 MPa were found on the tibial bone-implant interface. For the talar bone-implant interface, this was respectively 68.2 MPa and 39.0 MPa. TAR malalignment increases peak contact pressure and shear stress on the bone-implant interface. The highest peak contact pressure of 177 MPa was found for the 10° valgus malaligned tibial component, and the highest shear stress of 98.5 MPa was found for the 10° posterior malaligned talar model. High contact stresses were mainly located at the edges of the bone-implant interface and the fixation pegs of the talar component.

conclusionsThe current study demonstrates that TAR malalignment leads to increased peak stresses. High peak stresses could contribute to bone damage and subsequently reduced implant fixation, micromotion, and loosening. Further research is needed to investigate the relationship between increased contact stresses at the bone-implant interface and TAR failure.

Indexed as

Arthroplasty, Replacement, AnkleAnkle JointBiomechanical PhenomenaBone-Implant InterfaceFinite Element AnalysisHumansStress, MechanicalTibiaBone-implant interfaceContact stressFinite element modelingMalalignmentTotal ankle replacement

Identifiers

PMID35581630
PMCPMC9112518

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.