Evidence map›Paper›PMID 35579822›Full record

ArticleMusculoskeletal surgery2023

How to treat proximal and middle one-third humeral shaft fractures: the role of helical plates.

G Nicolaci, V Maes, N Lollino, G Putzeys

Abstract read
PubMed Publisher
In one paragraph

Article in Musculoskeletal surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Evolving fracture management: the role of helical plating in orthopaedic trauma surgery - a narrative review.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Review
  4. The effect of plate location on radial nerve palsy recovery time associated with humeral shaft fractures.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 2 countries.

G NicolaciUniversità degli Studi di Torino, Via Gianfranco Zuretti 29, 10126, Turin, Italy. ginicolaus@gmail.com.ORCID http://orcid.org/0000-0001-7457-3678
V MaesDepartment of Orthopaedic Surgery, University Hospitals Leuven, Leuven, Belgium.
N LollinoOspedale Civile E. Agnelli, SC Ortopedia e Traumatologia, Via Brigata Cagliari 39, 10064, Pinerolo, Italy.
G PutzeysDepartment of Orthopaedic Surgery, AZ Groeninge Hospital, President Kennedylaan 4, 8500, Kortrijk, Belgium.
AZ Groeninge · BEKU Leuven · BEOspedale Civile Edoardo Agnelli · ITUniversity of Turin · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the outcomes of patients affected by proximal and middle one-third humeral shaft fractures treated with humeral helical plates. MATERIAL AND

methodsFrom October 2016 to June 2020, twenty-four (twenty women, four men) underwent humeral reduction and fixation with humeral helical plates (A.L.P.S.® Proximal Humeral Plating System, Zimmer Biomet) that preserve deltoid muscle insertion and reduce the risk of iatrogenic radial nerve injury. At one and six months after surgery, standard antero-posterior and lateral radiographs were obtained, and at last follow-up (eighteen months on average), clinical evaluation was performed through range of motion assessment, Constant score and DASH score questionnaires. Only descriptive statistical analysis was conducted.

resultsAt six months, all fractures have healed. At last follow-up (average eighteen months, 13-28) mean Constant score was 71 (range 33-96), mean Dash score was 19.2 (range 1.7-63). The average range of motion was calculated as follows: flexion 137.8° (range 90-180); abduction 125.8° (range 85-180°); external rotation 55° (range 20-80°), internal rotation at L3 (range between scapulae-trochanter). Three patients experienced temporary radial nerve palsy from injury, while in one case, a temporary iatrogenic palsy occurred.

conclusionsIn our opinion, the helical plate may be an effective surgical tool for management of proximal and middle one-third diaphyseal humeral fractures. The humeral helical plate allows stable fixation avoiding the deltoid tuberosity proximally and radial nerve distally, thus increasing the possibility of rapid functional recovery after surgery.

Indexed as

Humeral FracturesShoulder FracturesBone PlatesFemaleFracture Fixation, InternalFracture HealingHumansHumerusIatrogenic DiseaseMaleRetrospective StudiesTreatment OutcomeComplex humeral fracturesDeltoid tuberosityDiaphyseal humeral fracturesHelical plates

Identifiers

PMID35579822
OpenAlexW4280515552

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.