Evidence map›Paper›PMID 35579090›Full record

ArticleJournal of applied clinical medical physics2022

Development of an anthropomorphic multimodality pelvic phantom for quantitative evaluation of a deep-learning-based synthetic computed tomography generation technique.

Hyeongmin Jin, Sung Young Lee, Hyun Joon An, Chang Heon Choi, Eui Kyu Chie, Hong-Gyun Wu, Jong Min Park, Sukwon Park, Jung-In Kim

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Hyeongmin JinDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Sung Young LeeDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Hyun Joon AnDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Chang Heon ChoiDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Eui Kyu ChieDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Hong-Gyun WuDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-3617-3870
Jong Min ParkDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Sukwon ParkDepartment of Radiation Oncology, Myongji Hospital, Goyang-si, Gyeonggi-do, Republic of Korea.
Jung-In KimDepartment of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
Seoul National University · KRSeoul National University Hospital · KRMyongji Hospital · KR

Funding

National Research Foundation of Korea (NRF) 2017M2A2A7A02020643National Research Foundation of Korea (NRF) 2019K1A3A1A80113183National Research Foundation of Korea (NRF) 2020M2D9A1093992
6 · The paper itself

Abstract

purposeThe objective of this study was to fabricate an anthropomorphic multimodality pelvic phantom to evaluate a deep-learning-based synthetic computed tomography (CT) algorithm for magnetic resonance (MR)-only radiotherapy.

methodsPolyurethane-based and silicone-based materials with various silicone oil concentrations were scanned using 0.35 T MR and CT scanner to determine the tissue surrogate. Five tissue surrogates were determined by comparing the organ intensity with patient CT and MR images. Patient-specific organ modeling for three-dimensional printing was performed by manually delineating the structures of interest. The phantom was finally fabricated by casting materials for each structure. For the quantitative evaluation, the mean and standard deviations were measured within the regions of interest on the MR, simulation CT (CT

resultsFor the prostate site, the mean MR intensities for the patient and phantom were 78.1 ± 13.8 and 86.5 ± 19.3, respectively. The mean intensity of the synthetic image was 30.9 Hounsfield unit (HU), which was comparable to that of the real CT phantom image. The original and synthetic CT intensities of the fat tissue in the phantom were -105.8 ± 4.9 HU and -107.8 ± 7.8 HU, respectively. For the target volume, the difference in D

conclusionThis work demonstrated that the anthropomorphic phantom was physiologically and geometrically similar to the patient organs and was employed to quantitatively evaluate the deep-learning-based synthetic CT algorithm.

Indexed as

Deep LearningHumansMagnetic Resonance ImagingMalePelvisPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedTomography, X-Ray Computed3D printingdeep learningmagnetic resonance-guided radiotherapymultimodality phantomsynthetic CT

Identifiers

PMID35579090
PMCPMC9359037
OpenAlexW4280503208

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.